CET Electric Technology
80
7464~7487
RW
Daily Profile #12
7488~7511
RW
Daily Profile #13
7512~7535
RW
Daily Profile #14
7536~7559
RW
Daily Profile #15
7560~7583
RW
Daily Profile #16
7584~7607
RW
Daily Profile #17
7608~7631
RW
Daily Profile #18
7632~7655
RW
Daily Profile #19
7656~7679
RW
Daily Profile #20
Table 5-47 TOU #1’s Daily Profile Setup
Register
Property
Description
Format
8200~8223
RW
Daily Profile #1
See Table 5-49
Daily Profile Data
Structure
8224~8247
RW
Daily Profile #2
8248~8271
RW
Daily Profile #3
8272~8295
RW
Daily Profile #4
8296~8319
RW
Daily Profile #5
8320~8343
RW
Daily Profile #6
8344~8367
RW
Daily Profile #7
8368~8391
RW
Daily Profile #8
8392~8415
RW
Daily Profile #9
8416~8439
RW
Daily Profile #10
8440~8463
RW
Daily Profile #11
8464~8487
RW
Daily Profile #12
8488~8511
RW
Daily Profile #13
8512~8535
RW
Daily Profile #14
8536~8559
RW
Daily Profile #15
8560~8583
RW
Daily Profile #16
8584~8607
RW
Daily Profile #17
8608~8631
RW
Daily Profile #18
8632~8655
RW
Daily Profile #19
8656~8679
RW
Daily Profile #20
Table 5-48 TOU #2’s Daily Profile Setup
Offset
Property
Description
Format
Note
+0
RW
Period #1 Start Time
UINT16
0x0000
+1
RW
Period #1 Tariff
UINT16
0=T1, …, 7=T8
+2
RW
Period #2
Start Time
High-order Byte: Hour
UINT16
0 ≤ Hour < 24
Low-order Byte: Min
Min = 0, 15, 30, 45
+3
RW
Period #2 Tariff
UINT16
0=T1, …, 7=T8
+4
RW
Period #3 Start Time
UINT16
See Period #2 Start Time
+5
RW
Period #3 Tariff
UINT16
0=T1, …, 7=T8
+6
RW
Period #4 Start Time
UINT16
See Period #2 Start Time
+7
RW
Period #4 Tariff
UINT16
0=T1, …, 7=T8
+8
RW
Period #5 Start Time
UINT16
See Period #2 Start Time
+9
RW
Period #5 Tariff
UINT16
0=T1, …, 7=T8
+10
RW
Period #6 Start Time
UINT16
See Period #2 Start Time
+11
RW
Period #6 Tariff
UINT16
0=T1, …, 7=T8
+12
RW
Period #7 Start Time
UINT16
See Period #2 Start Time
+13
RW
Period #7 Tariff
UINT16
0=T1, …, 7=T8
+14
RW
Period #8 Start Time
UINT16
See Period #2 Start Time
+15
RW
Period #8 Tariff
UINT16
0=T1, …, 7=T8
+16
RW
Period #9 Start Time
UINT16
See Period #2 Start Time
+17
RW
Period #9 Tariff
UINT16
0=T1, …, 7=T8
+18
RW
Period #10 Start Time
UINT16
See Period #2 Start Time
+19
RW
Period #10 Tariff
UINT16
0=T1, …, 7=T8
+20
RW
Period #11 Start Time
UINT16
See Period #2 Start Time
+21
RW
Period #11 Tariff
UINT16
0=T1, …, 7=T8
+22
RW
Period #12 Start Time
UINT16
See Period #2 Start Time
+23
RW
Period #12 Tariff
UINT16
0=T1, …, 7=T8
Table 5-49 Daily Profile Data Structure
Notes:
1)
Daily Profile #1’s Period #1 Start Time is always 00:00 and cannot be modified.
2)
Setting a Period’s Start Time as 0xFFFF terminates the Daily Profile’s settings. All later Daily Profile’ setup parameters will
be ignored, and the previous Period’s duration is from its Start Time to the end of the day.
3)
The interval of a period should be 15n (n=1, 2, etc.) minutes.
4)
The Start Time of a particular Period must be later than the previous Period’s .