Chapter 5 – Parameter List
5-10
5.7 [FG2] Function Group 2 parameter group
CODE
Com.
Addr
Description
LCD Keypad
Display
Setting Range
Run
Adj.
Page
FG2-00
9400
Jump to Desired Code #
Jump Code
1 to 95
6-18
FG2-01
9401
Last trip 1
Last Trip-1
Press
[ENTER]
then
key to see Hz,
Amps,
Mode and
trip
time then
[ENTER]
Display
FG2-02
9402
Last trip 2
Last Trip-2
FG2-03
9403
Last trip 3
Last Trip-3
FG2-04
9404
Last trip 4
Last Trip-4
FG2-05
9405
Last trip 5
Last Trip-5
FG2-06
9406
Erase trips
Erase Trips
0 (No)
1 (Yes)
FG2-07
9407
Last Trip Time
LastTripTime
X:XX:XX:XX:XX:X
Display
FG2-08
9408
Power On Time
On-Time
X:XX:XX:XX:XX:X
FG2-09
9409
Run-time
Run-Time
X:XX:XX:XX:XX:X
FG2-10
940A
Dwell Time
Dwell Time
0 to 6000 [sec]
FG2-11
940B
Dwell/
Sleep Boost
Frequency
Dwell Freq
FG1-32 to FG1-30
FG2-12
940C
Jump Frequency Selection
Jump Freq
0 (No)
1 (Yes)
FG2-13
940D
Jump Frequency 1 Low
Jump Low 1
FG1-32 to FG2-14
FG2-14
940E
Jump Frequency 1 High
Jump High 1
FG2-13 to Max
FG2-15
940F
Jump Frequency 2 Low
Jump Low 2
FG1-32 to FG2-16
FG2-16
9410
Jump Frequency 2 High
Jump High 2
FG2-15 to Max
FG2-17
9411
Jump Frequency 3 Low
Jump Low 3
FG1-32 to FG2-18
FG2-18
9412
Jump Frequency 3 High
Jump High 3
FG2-17 to Max
FG2-19
9413
Power ON Start Selection
Power On Run
0 (No)
6-19
1 (Yes)
FG2-20
9414
Start Delay
Time
after Power Up
PwrUpRun Dly
0 to 9999 sec
FG2-21
9415
Restart after Fault Reset
RST Restart
0 (No)
1 (Yes)
FG2-22
9416
IPF Mode
IPF Mode
0 (No)
1 (Yes)
FG2-24
9418
Retry Selection
Retry Mode
0 (No)
1 (Yes)
FG2-25
9419
Number of Auto Retry
Retry Number
0 to 10
FG2-26
941A
Delay Time Before Auto Retry
Retry Delay
0 to 6000 [sec]
FG2-27
941B
Flying Start Level
FlySt Level
50 to160 [%]
FG2-30
941C
Flying Start Mode
FlySt Mode
0 (No)
1 (Yes)
FG2-42
942A
Rated Motor Slip RPM
Rated Slip
0 to 16% of motor
RPM
FG2-44
942C
No Load Motor Current (RMS)
Noload Curr
0.5 to 999.9 [A]
FG2-46
942E
Load Inertia
InertiaRate
1 to 40
6-20
FG2-47
942F
Scale for Motor Speed Display
RPM Scale
1 to 1000 [%]
FG2-49
9430
PWM Type Selection
PWM Mode
0 (Normal )
1 (Low leakage)
FG2-50
9432
Safety Stop Decel Time
Safety Time
1.0~100.0
FG2-51
9433
Safety Stop Gain
SafetyGain
2~500
FG2-60
943C
Control Mode Selection
Control Mode
0 (V/F)
1 (Slip compen)
2 (Sensorless)
Содержание CI-007-P2
Страница 23: ......
Страница 107: ......
Страница 109: ...Chapter 6 Parameter Description 7 2 7 3 PID control Sleep mode with Sleep Pressure Boost function diagram...
Страница 110: ...Chapter 6 Parameter Description 7 4 PID control with Pipe Broken function diagram...
Страница 111: ...Chapter 6 Parameter Description 7 4 7 5 PID control with Pre PID function diagram...
Страница 112: ...Chapter 6 Parameter Description 7 5 7 6 PID Control Setting Notes...
Страница 113: ......
Страница 126: ...Chapter 9 Options 9 7 Conduit box for 030 040HP VFD Conduit box for 050 075HP VFD Conduit box for 100 125HP VFD...