GFCI is tripped or continues
to trip during use.
An imbalance between
the ungrounded (hot) and
grounded (neutral) power.
Do not attempt to operate
when this condition exists. Return
to authorized service center for
proper repair.
Ready light on operator
panel does not light up.
Power cord or machine is not
receiving voltage.
Check for cuts in power cord(s),
tripped circuit breaker at electrical
source. Check to make sure
electrical inlet connection at
machine is secure.
Hopper is not correctly attached
to the base.
See
Setup section on page 12
for proper orientation of hopper
and base.
Agitator and or main circuit
breaker is tripped or not in the
“on” position.
Both the main and agitator circuit
breakers must be in the “on”
position in order for the machine
to operate. Reset tripped circuit
breaker(s).
GFCI tripped.
The GFCI must be in the “on”
position in order for the machine to
operate. Reset tripped GFCI.
Note: The ready light will illuminate
unless there is an internal fault
inside the GFCI device itself.