19
TrueComfort System
Troubleshooting
PRObLEM
LIkELY CAUSE
REMEDY
Machine will not start
or operate.
Main circuit breaker is tripped or is
not in the “on” position.
At electrical panel, check for tripped
circuit breaker. Reset the circuit breaker
to the “on” position.
Power cord is not receiving
electricity from electrical source.
Check for a tripped circuit breaker
at the electrical source or a loose
connection at the electrical outlet.
Check extension cord for damage,
such as cuts in outer jacket or exposed
wires. Do not use until repair is made.
Check to ensure that the power cord
connection at the electrical inlet on
machine is secure.
GFCI has tripped.
At electrical panel, check for tripped
GFCI button. If tripped, the upper
button of GFCI will be “popped” out;
push to re-set.
Hopper is not correctly attached
to the base and/or is not securely
fastened.
Refer to the setup section of this
manual for correct orientation of the
hopper & base. Reattach hopper to
base using the four hopper latches.
Wireless remote does not
operate the machine.
Location of the machine.
The structure which is being insulated
may be causing the signal interference.
Move the machine to another location
which may allow for a better signal
between the transmitter and the
receiver.
Batteries within the transmitter may
be weak and need to be replaced.
The transmitter has a built-in indicator
light which, when depressed, causes
the indicator to illuminate. If the
indicator light does not light up,
batteries may be weak and need to be
replaced. Use two (2) AA batteries.