23
T
roubleshooting
PRObLEM
LIkELY CAUSE
REMEDY
When the agitation system
starts or is running, ratcheting
noise occurs within the base of
machine.
Agitator chain is “jumping” or
skipping teeth on the sprockets.
Loosen chain tensioner assembly,
and move tensioner towards chain until
chain is tight and any slack is taken up
in chain.
The chain on the agitator motor to
the airlock is loose and is causing
the chain to “jump or skip.”
Loosen motor mount screws. Adjust
motor mount until correct tension is
applied to the chain. Retighten motor
mount screws.
Machine jams during feeding.
Overfeeding/loading of hopper.
Allow only 1/2 bag at a time during the
feeding process. Wait until contents of
the first 1/2 bag have gone down past
the refill line before loading the next 1/2
bag.
Incorrect orientation of bag.
The correct orientation of the 1/2 bag is
critical to the machine. Align the arrows
on bag in the same direction as the
arrows located on the machine.
Agitator circuit breaker trips.
Overfeeding/loading of hopper.
Allow only 1/2 bag at a time during the
feeding process. Wait until contents of
the first 1/2 bag have gone down past
the refill line before loading next 1/2 bag.
Do not force feed the material!
Low voltage; too long of
extension cord.
Shorten length of extension cord to
recommended lengths.
See the
Generator and Extension
Cords section on page 17.
Foreign object inside machine.
Disconnect power cord at the
machine. Remove insulation from the
base. Locate and remove the foreign
object. Reattach hopper.