   Installation Guide 

 

 

FibeAir

®

 IP

-

20F 

 

 
 
 

February 2020  |  Rev A.06

 

© Copyright 2020 by Ceragon Networks Ltd. All rights reserved.

 

Содержание FibeAir IP-20F

Страница 1: ...Installation Guide FibeAir IP 20F February 2020 Rev A 06 Copyright 2020 by Ceragon Networks Ltd All rights reserved...

Страница 2: ...use open source software among them O S software released under the GPL or GPL alike license Open Source License Inasmuch that such software is being used it is released under the Open Source License...

Страница 3: ...g for Installation 22 2 1 Transportation Storage 23 2 2 Inspection 24 2 3 Unpacking Equipment at the Site 25 3 Installing the IP 20F IDU 26 3 1 Kits required to perform the installation 27 3 2 Tools 2...

Страница 4: ...l Specifications for IDU 48 8 2 Environmental Specifications for RFU 49 8 3 Mechanical Specifications 50 8 4 Power Consumption Specifications 51 9 Acceptance Commissioning Procedures 52 9 1 Site Accep...

Страница 5: ...Pin Connections 13 Figure 5 SM Card and Cover 21 Figure 6 IDU Full Configuration 26 Figure 7 Power Supply Grounding 33 Figure 8 Correct Wiring of Power Connector 34 Figure 9 Connecting the Power Cable...

Страница 6: ...Installation Guide for FibeAir IP 20F Page 6 of 63 Ceragon Proprietary and Confidential List of Tables Table 1 IDU RFU Cable Connection 38 Table 2 IDU Mechanical Specifications 50...

Страница 7: ...to strong high frequency electromagnetic fields may cause thermal damage to personnel The eye cornea and lens is easily exposed Any unnecessary exposure is undesirable and should be avoided In radio r...

Страница 8: ...s Laser Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure The optical interface must only be serviced by qualifie...

Страница 9: ...his own expense Restricted Access Area DC powered equipment should only be installed in a Restricted Access Area Installation Codes The equipment must be installed according to country national electr...

Страница 10: ...n IP 20F system consists of an IP 20F indoor unit IDU and one or more radio frequency units RFUs This manual provides instructions for the installation of the IP 20F IDU only Some features described i...

Страница 11: ...using an electrical or optical fiber connection an external DC power cable is required An IP 20F IDU contains Three 1 GbE combo interfaces Two dual mode GbE or cascading combo interfaces Two combo RJ...

Страница 12: ...GbE 2 SFP 2 can be configured as normal Ethernet traffic interfaces or as cascading interfaces When operating in cascading mode these interfaces can handle hybrid Ethernet and Native TDM traffic enab...

Страница 13: ...Switch TX TX RX RX TX TX RX RX Port 1 Port 2 1 2 3 4 5 6 7 8 RJ 45 Connector female Figure 4 Management Interface Pin Connections 1 2 1 Management Interface Cable Options If the user only needs to use...

Страница 14: ...lation Guide for FibeAir IP 20F Page 14 of 63 Ceragon Proprietary and Confidential 1 3 E1 DS1 Interface FibeAir IP 20F includes an MDR69 connector in which 16 E1 interfaces are available ports 1 throu...

Страница 15: ...1 1 STM 1 OC 3 protection configuration The STM 1 OC 3 port provides an interface for up to 63 E1 or 84 DS1 lines inside a standard channelized STM 1 or OC 3 signal Each E1 DS1 line is transported by...

Страница 16: ...erfaces FibeAir IP 20F includes two combo radio interfaces RJ 45 or SFP RFU1 and RFU2 A third interface can also be used as a combo radio interface RJ 45 or SFP RFU3 Note For some RFUs PoE power can b...

Страница 17: ...e power sources for power redundancy The IP 20F monitors the power supply for under voltage and includes reverse polarity protection so that if the positive and negative inputs are mixed up the system...

Страница 18: ...Ceragon Proprietary and Confidential 1 7 Synchronization Interface FibeAir IP 20F includes an RJ 45 synchronization interface for T3 clock input and T4 clock output The interface is the lower RJ 45 i...

Страница 19: ...Page 19 of 63 Ceragon Proprietary and Confidential 1 8 Terminal Interface FibeAir IP 20F includes an RJ 45 terminal interface RS 232 A local craft terminal can be connected to the terminal interface...

Страница 20: ...IP 20F includes a DB9 dry contact external alarms interface The external alarms interface supports five input alarms and a single output alarm The input alarms are configurable according to 1 Interme...

Страница 21: ...nd software for the IDU The SM Card is embedded in the SM Card plastic cover that is located under the SM card aluminum cover In the event of IDU replacement re using the existing SM card cover is nec...

Страница 22: ...eAir IP 20F Page 22 of 63 Ceragon Proprietary and Confidential 2 Preparing for Installation This section provides instructions for transporting inspecting and unpacking the equipment for an IP 20F sys...

Страница 23: ...y forklift trucks and slings The cargo must be kept dry during transport and storage For sea transport deck side shipment is not permitted Carrier owned cargo containers should be used It is recommend...

Страница 24: ...prietary and Confidential 2 2 Inspection Check the packing lists and ensure that correct parts numbers quantities of goods have arrived Inspect for any damage on the cases and equipment Report any dam...

Страница 25: ...al that whenever unpacking or disassembling the equipment and handling printed circuit boards special precautions should be taken to avoid ESD Electrostatic Static Discharge Generally units with stati...

Страница 26: ...on Guide for FibeAir IP 20F Page 26 of 63 Ceragon Proprietary and Confidential 3 Installing the IP 20F IDU This section provides instructions for installing a FibeAir IP 20F IDU Figure 6 IDU Full Conf...

Страница 27: ...allation Guide for FibeAir IP 20F Page 27 of 63 Ceragon Proprietary and Confidential 3 1 Kits required to perform the installation Description Quantity IP 20F chassis 1 19 rack sub rack 1 SM Card Cove...

Страница 28: ...Installation Guide for FibeAir IP 20F Page 28 of 63 Ceragon Proprietary and Confidential 3 2 Tools Philips screwdriver Flat screwdriver...

Страница 29: ...he rack as shown in the following figures Use four screws not supplied with the installation kit to fasten the IDU to the rack If you are installing multiple IP 20F units in a single rack make sure to...

Страница 30: ...st have a thickness of at least 12 AWG If the grounding cable is longer than 2 meters a 6 AWG cable is required The recommended resistance between main rack grounding and the IP 20F chassis is 5 m or...

Страница 31: ...hat you can insert it into the new IDU The SM Card holds the configuration and software for the IDU The SM Card is embedded in the SM Card plastic cover that is located under the SM card aluminum cove...

Страница 32: ...IDU or if you are upgrading the SM Card the old IDU make sure that there is no foreign matter blocking the sockets in the opening where the SM Card is installed 5 Gently place the SM Card in its plac...

Страница 33: ...necting the Power Cable Important Before connecting the power supply to the IP 20F unit you must verify that the positive pole in the external power supply is grounded Power supply grounding should be...

Страница 34: ...ing power cables are available for use with an IP 20F unit Ceragon Part Number Marketing Model Marketing Description WA 0567 0 CBL PWR OE OE 16A 2 2m Power cable Open end Open end 16A 2 2m WA 0568 0 C...

Страница 35: ...d Confidential 4 Insert the wires into the connector 5 Secure the wires in the connector with the screws 6 Plug the connector into the IP 20F power interface and tighten the two screws on the sides of...

Страница 36: ...Installation Guide for FibeAir IP 20F Page 36 of 63 Ceragon Proprietary and Confidential 4 1 Power Supply Notes...

Страница 37: ...nit has more than one supply connection Remove all power from the unit for servicing Important Make sure to use a circuit breaker to protect the circuit from damage by short or overload In a building...

Страница 38: ...F IP 20G and IP 20GX For an RFU D RFU E or RFU S connecting to an optical RFU interface and for an RFU D HP connecting to either an electrical or an optical RFU interface an external DC power cable is...

Страница 39: ...al Configuration This section describes how to establish a management connection with the IP 20F unit and lists the configuration steps that should be performed in order to enable basic radio connecti...

Страница 40: ...Configure the following settings for the COM port you are using on your PC or laptop o Bits per Second 115 200 o Data Bits 8 o Parity None o Stop Bits 1 o Flow Control None 7 1 2 Connecting to the Uni...

Страница 41: ...255 255 0 Note the initial settings before changing Note The chassis IP address as well as password should be changed before the system is set in operation For more information on these procedures re...

Страница 42: ...etary and Confidential 7 2 Logging On 1 Open an Internet browser Internet Explorer or Mozilla Firefox 2 Type in the default IP address 192 168 1 1 in the Address Bar Figure 12 Login Window 3 Enter the...

Страница 43: ...activated the password must meet the following criteria o Password length must be at least eight characters o Password must include characters of at least three of the following character types lower...

Страница 44: ...ther side of the hop may be lost By default all elements have the same IP settings IP address 192 168 1 1 Subnet mask 255 255 255 0 Note After the new IP address is set the contact with the element wi...

Страница 45: ...nning Configuration files must also be compatible with the type of IP 20 device For example a configuration file created for IP 20G cannot be applied to an IP 20F device If you need to change the IDU...

Страница 46: ...click Submit Progress is updated in the Quick Configuration From File page When the configuration is complete the unit reboots If the configuration file includes changing from ETSI to ANSI mode the u...

Страница 47: ...Installation Guide for FibeAir IP 20F Page 47 of 63 Ceragon Proprietary and Confidential 8 Specifications...

Страница 48: ...rating ETSI EN 300 019 1 3 Class 3 2 Temperature o 5 C 23 F to 55 C 131 F Temperature range for continuous operating temperature with high reliability o 25 C 13 F to 65 C 149 F Temperature range for e...

Страница 49: ...ifications for RFU Operating ETSI EN 300 019 1 4 Class 4 1 Temperature o 33 C 27 F to 55 C 131 F Temperature range for continuous operating temperature with high reliability o 45 C 49 F to 60 C 140 F...

Страница 50: ...cable with RJ 45 connectors on the RFU and one of the RJ 45 RFU interfaces on the IP 20F They can also be connected to the IDU over optical fiber cables via one of the optical SFP RFU interfaces on th...

Страница 51: ...he maximum power consumption for IP 20F IDU and supported RFUs The maximum power consumption for the entire system is the sum of the IDU and the RFUs connecting to it Configuration Power W Comments ID...

Страница 52: ...erify correct installation and operation of the installed link and the interoperability with customer end equipment Ceragon s Acceptance and Commissioning procedure includes the following stages Site...

Страница 53: ...product The checklist below summarizes the installation requirements of the site SITE ACCEPTANCE CHECKLIST 1 SITE INFORMATION Customer Radio model Site name Site code Radio link code Site address 2 AN...

Страница 54: ...h unit polarization is as per link requirements OK SITE ACCEPTANCE CHECKLIST continued 4 RADIO FREQUENCY UNIT RFU Type of RFU mount Direct or Remote mount RFU is securely mounted to the antenna or pol...

Страница 55: ...te specifications OK Lightning protection type and model Cable point of entry to building shelter is weather proof OK Cable ends are properly labeled OK SITE ACCEPTANCE CHECKLIST continued 7 FLEXIBLE...

Страница 56: ...is secured tidy and visibly labeled OK 9 DC POWER SUPPLY Two Inputs Measured DC voltage input to the IDU 40 5 to 60 VDC Power Supply maximum current at least 3 Ampere per carrier Power Supply is prop...

Страница 57: ...Installation Guide for FibeAir IP 20F Page 57 of 63 Ceragon Proprietary and Confidential Site accepted by Name Title Company Signature Date Site approved by Name Title Company Signature Date...

Страница 58: ...gree cone of protection of existing lightning conductors additional lightning protectors should be installed All steelwork is Galvanized or Stainless Steel as appropriate to prevent corrosion 2 Antenn...

Страница 59: ...s are secure and correctly terminated All labeling is complete as per site requirements Labeling is specific to each customer At a site with only one installation labeling may be unnecessary However a...

Страница 60: ...est for at least one hour load rate as per Ceragon s specifications for the chosen MRMC Connect Ethernet Packet Analyzer to the FE port Use physical loop at remote end or connect second analyzer Run P...

Страница 61: ...rmation regarding the installed link and contains a checklist of all recommended commissioning tests Maintaining the Commissioning Log is important for tracking your installations and to provide essen...

Страница 62: ...equency MHz Link ID Tx power dBm ATPC on off ATPC ref level RFU Polarization 3 ANTENNA AND RFU MOUNT Site 1 Site 2 Antenna vendor and model Antenna size Mounting type Mounting losses 4 LINK PARAMETERS...

Страница 63: ...Pass RFU loopback Pass Pass Radio BER Pass Pass FE test Pass Pass GbE test Pass Pass 6 MANAGEMENT CONFIGURATION Site 1 Site 2 Eth IP Address Eth IP mask Default router In band VLAN 7 REMARKS NOTES 8 I...