Installation Guide for FibeAir IP-20F
Page 8 of 63
Ceragon Proprietary and Confidential
ESD
This equipment contains components which are sensitive to "ESD" (Electro Static
Discharge). Therefore, ESD protection measures must be observed when touching the
IDU.
Anyone responsible for the installation or maintenance of the FibeAir IDU must use an
ESD Wrist Strap.
Additional precautions include personnel grounding, grounding of work bench,
grounding of tools and instruments as well as transport and storage in special antistatic
bags and boxes.
Laser
Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
The optical interface must only be serviced by qualified personnel, who are aware of
the hazards involved to repair laser products.
When handling laser products the following precautions must be taken:
•
Never look directly into an open connector or optical cable.
•
Before disconnecting an optical cable from the optical transmitter, the power
should be switched off. If this is not possible, the cable must be disconnected
from the transmitter before it is disconnected from the receiver.
•
When the cable is reconnected it must be connected to the receiver before it
is connected to the transmitter.