Installation Guide for FibeAir IP-20F
Page 38 of 63
Ceragon Proprietary and Confidential
6.
IDU
-
RFU Cable Connection
RFU-D, RFU-D-HP, RFU-E, and RFU-S can be connected to the IP-20F IDU via a standard
CAT-5e or preferably CAT-6/6a cable, with RJ-45 connectors on the RFU and an RJ-45
connector on the IDU. They can also be connected to the IDU over optical fiber cables
via the optical (SFP) RFU interface on the IDU.
For an RFU-D, RFU-E, or RFU-S connecting to an electrical RFU interface, the cable can
carry both the data and the DC power required for the RFU. For configuration
instructions, refer to the
User Guide for FibeAir IP-20F, IP-20G, and IP-20GX
.
For an RFU-D, RFU-E, or RFU-S connecting to an optical RFU interface, and for an RFU-
D-HP connecting to either an electrical or an optical RFU interface, an external DC
power cable is required to supply power to the RFU.
Table 1: IDU-RFU Cable Connection
RFU
Interface
Cable Type
Maximum Length
6-11 GHz
13-42 GHz
RFU-D
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
65m
100m
CAT-6a (22 AWG)
110m
150m
DC Power
DC (18 AWG)
100m
DC (12 AWG)
101m-300m
RFU-S
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
130m
150m
CAT-6a (22 AWG)
150m
150m
DC Power
DC (18 AWG)
150m
DC (14 AWG)
151m-300m
RFU-D-HP
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
150m
CAT-6a (22 AWG)
150m
DC Power
DC (14 AWG)
100m
DC (10 AWG)
101m-300m
RFU-E
Optical
Fiber
300m
Electrical
CAT-5e (24 AWG)
130m
CAT-6a (22 AWG)
150m
DC Power
DC (18 AWG)
150m
DC (14 AWG)
151m-300m