page 30
Collision sensitivity adjustment
13. Adjust the sensitivity on the controller such
that the gate(s) will open and close reliably,
but not cause damage to persons or objects
in the path of the gate(s).
14. The motor will just stop when the gate(s) hits
an obstruction while opening or closing.
17. Trigger the gate(s) and when the gate(s) have
traveled approximately halfway through the
opening or closing movement, obstruct the
gate(s) noting the effort required to stop
them.
16. Start with the potentiometers set to a midway
position.
15. There are two sensitivity potentiometers on
the CP77/24V controller. The left-hand
potentiometer is used to set the sensitivity of
both the master and slave gate(s) when
opening. The right-hand potentiometer is
used when the gate(s) are closing.
FIGURE 41