10. Adjust the open limit switch by loosening the screw and then moving the disc until the open
microswitch is triggered in the desired position.
11. Close the foundation box by adding the cover plate, and securing it to the box via the cover
fixing brackets.
Open endstop
3. It is possible to use the internal limit switch
to stop the gates in the open position.
4. Alternatively mechanical endstops can be
used, mounted where each leaf swings to, in
the open position.
5. The
limit switch disc
should already have
been mounted onto the motor’s output
shaft at an earlier stage.
6. Assemble the microswitch group in either of
the positions available, depending on the
type of installation.
7. Only one of the two microswitches provided will be used.
8. Determine which microswitch will be activated when the gate opens.
9. Select the
common
and
normally-open
terminals of this microswitch to be connected to the
controller:
Black
– Common
Blue
– Normally-open: use
Red
– Normally-closed: ignore