Input voltage
Motor voltage
Motor power supply
Battery charger
Current consumption (mains)
Current consumption (motor at rated load)
Current consumption
(controller and receiver only - standby)
Operator output torque - maximum
Typical gate opening time (90° opening)
Operator reversible / irreversible
Manual Override
Maximum number of operations per day
Duty cycle - mains present
Operations in standby
With 7Ah battery
Half day
One day
With 40Ah battery
Half day
One day
Collision sensing
Operating temperature range
Gearbox housing protection
Receiver type
Mass of unit packed
Operator
Foundation box
Controller housing
Packaging dimensions
Operator
Foundation box
Controller housing
220V AC ± 10%, 50Hz
24V DC
Battery driven (standard capacity - 2 x 7Ah)
500mA @ 27.5V DC
60mA
5A
360Nm
15-23 seconds
Irreversible
Key release
200
50%
26
19
155
149
Electronic
-15°C to +50°C
IP67
External
11.6kg
8.6kg
4kg (excludes batteries)
350 x 150 x 200mm
400 x 400 x 250mm
480 x 320 x 150mm
Can operate off a solar supply, consult Centurion Systems for assistance
Can increase battery capacity for longer standby times
Based on 25°C ambient temperature and unit not in direct sunlight
Based on an output torque of less than 50% of maximum
Based on double kit excluding infrared safety beams
page 8
70mA