background image

 

 

-  7  -

                                      INSTALLATION MANUAL –  RDO 

 

 

D.

 

Check For Correct Function Of The Door 

 

Before beginning the installation of the RDO II, check that the garage door is functioning correctly. The garage 

door must be well-balanced and operate smoothly and freely. When opened to between 900~1200mm from the 

floor and released, the garage door should remain in one fixed position and not rise or fall more than 100mm. It 

should not bind or stick in the side tracks. The ideal operational effort required to open or close the garage door 

should not exceed a force of 15kg. (Refer Item 3, Page 2) 

 

Important Note: The RDO II must not be installed on a poorly-adjusted, worn or damaged door. 

 

E.

 

Weight Bar 

 

The main purpose of the weight bar is to eliminate the possibility of the garage door curtain “ballooning” when 

starting from the fully open position. With the weight bar fitted, the garage door should have a natural tendency 

to lightly free fall from the mid-open position. 

 

F.

 

Left / Right-Hand Installation 

 

The RDO II has been factory-set to be installed on the right-hand end of your garage door (when viewed from 

inside the garage looking out). Flip dipswitch 6 to the ‘ON’ position for a left-hand installation, and to the ‘OFF’ 

position for a right-hand installation. Please refer to Section 13.4 for further information. 

 

G.

 

Control Box Location 

   

Mount the Control Box on a smooth, flat surface. The area must be completely free from   

exposure to water, either direct (rain, garden hose, sprinklers, etc.) or indirect   

(seepage either through or down the internal face of the wall). The Control Box contains 

sensitive electronics which will sustain damage as a result of 

any 

water ingress.   

Water-damaged electronics are not covered under the terms of the opener warranty.   

 

Important Note: The control box is not waterproof! 

 

H.

 

Battery Charger

 

 

 

The plug-in battery charger is provided to keep the batteries charged to an optimum voltage. A green coloured 

LED, located on the charger casing will illuminate to indicate that the charger has been connected to an active 

power supply.   

Important Note: Do not mount the charger any further away from the control box than the connection 

cable allows. Please ensure that a 220V mains point is provided at the control box for the charger. 

 

I.

 

Battery Cable Connection 

 

In order to conserve battery power prior to installation, the RDO II is 

supplied with the positive (red) battery cable disconnected from the   

 

battery terminal.   

Connect this cable as follows prior to commencing the installation; 

Remove the Control Box lid and connect the red cable to the positive   

 

(+) battery terminal as depicted in Figure 6 (Item 7).   

Once connected, the lid can be refitted. 

 

 

 

 

 

 

                                                                          

                                                                                Fig. 6

 

 

Содержание RDO II

Страница 1: ...1...

Страница 2: ...to installation of the RDO II 6 The counterbalance springs on sectional type doors must be properly lubricated between all of the coils with heavy automotive bearing grease Failure to adequately lubr...

Страница 3: ...vide additional peace of mind In some countries it is a mandate of law to fit Safety Beams It is the sole responsibility of the owner installer to fit Safety Beams in those countries which so require...

Страница 4: ...ayment has been received for such goods Australian customers Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a...

Страница 5: ...5 INSTALLATION MANUAL RDO Fig 1 Fig 2 Fig 2A Fig 3 Fig 3A...

Страница 6: ...5mm as indicated Important Notes The fixing distance may vary from garage door to garage door depending on the distance that the garage door drum wheel has been set inside the garage door curtain If t...

Страница 7: ...d installation Please refer to Section 13 4 for further information G Control Box Location Mount the Control Box on a smooth flat surface The area must be completely free from exposure to water either...

Страница 8: ...epth if the Control Box will not hook onto the screws or if the Control Box does hook on but is loose 1 7 At this stage DO NOT plug the Charger into a power socket 2 Fitting Of Drive Unit to The Door...

Страница 9: ...f the Drive Unit 2 10 Refit the garage door mounting bracket to the wall The U Bolt slots in the door bracket must align with the U bolt mounting slots in the Drive Unit Fig 10 2 11 Important Note In...

Страница 10: ...re that there are no persons and or property near or directly under the path of the garage door Fig 11 Fig 12 5 Fitting of Weight Bar 5 1 Fit the weight bar to the top edge of the garage door bottom r...

Страница 11: ...tion of the Close Limit Upper Switch until you hear the switch click Once the Open Limit Switch clicks continue to rotate the Cam a further 10 degrees or so towards the switch 8 4 To check the Close L...

Страница 12: ...ating parameters will be learned in the following order Open Stroke 1 Alignment stroke Close Stroke 1 Learn run time between Open Limit Point and Close Limit Point during Close Cycle 1 the RDO II will...

Страница 13: ...he Control Box and Lamp Covers switch power on at power supply Fig 17 Entering Safety Obstruction Force Adjustment mode Hinge open the Courtesy Lamp Cover to expose the adjustment controls Press and h...

Страница 14: ...force anti clockwise to decrease force and then repeat the previous testing steps Close direction With the garage door in the fully open position stand inside the garage just behind the path of the ga...

Страница 15: ...A button will have to be pressed and held for at least three seconds in order to be learned into the controller s memory Important notice It is of the utmost importance that the Forced Learn procedure...

Страница 16: ...be pressed once The LED indicator will flash twice every two seconds to confirm that Function Two Learn has been selected Take the remote control or wall pendant that must be learned into the system...

Страница 17: ...or wall pendant is learned and automatically exit after this time The function can be learned to any button provided that the button has not yet been learned to another function 12 4 Function Four Au...

Страница 18: ...your property by ensuring that your garage door is never unintentionally left open Autoclose will automatically close the garage door Three seconds after reaching the open limit point provided that a...

Страница 19: ...y damage the transformer and Control Board Always ensure that replacement bulb is rated at 24V and no more than 2W 13 4 Dipswitches The Dipswitches located on the Control Board Figure 20 enable or dis...

Страница 20: ...or objects which may pass within the path of the moving garage door The RDO II will commence to Safety Reverse if the Safety Beams become momentarily or permanently interrupted during a Close Cycle M...

Страница 21: ...rage door as it approaches a limit point the RDO II ensures quieter garage door closing and prolonged RDO II and garage door life Standard function within Adaptive Mode only Adaptive Mode is factory c...

Страница 22: ...uction Force setting is too high and may require adjustment Refer to Installation instructions Door moves downwards and reverses itself upwards Safety Obstruction Force setting is too low and may requ...

Страница 23: ...23 INSTALLATION MANUAL RDO Notes...

Страница 24: ...24 INSTALLATION MANUAL RDO...

Отзывы: