- 13 -
INSTALLATION MANUAL – RDO
Forced learn
•
A Forced Learn may be initiated by holding down the “Learn” Button for three seconds – LED Indicator will
begin to quick flash
•
Cycle the
RDO II
through five complete uninterrupted strokes (commencing from the close limit point) in order
for it to complete the learning process. The LED Indicator will cease to quick flash once learning has been
completed
Important Note: During a Forced Learn, the Safety Obstruction Force values default to a maximum setting.
Encountering a solid obstruction during the course of the initial learning cycles may result in garage door and /
or property damage. It is recommended that the learning cycles be carefully supervised during this time.
Automatic Re-Learn
•
A re-learn of Drive Force and Run Time parameters will be automatically initiated immediately subsequent to
either one of the following occurrences;
•
Run Time deviation becoming excessive
•
Safety Reversing on three consecutive occasions
•
Safety Stopping on three consecutive occasions
•
During this period the LED Indicator will quick flash
11.2. Manual (M) Mode
Enabling
•
If Adaptive Mode is your desired selection, then refer back to Section.11.1. to
enable Manual Mode;
•
switch off power at power supply
•
remove the Courtesy Lamp and Control Box Covers to expose the Control
Board
•
select Dipswitch No.1 to the “OFF” position
•
replace the Control Box and Lamp Covers
•
switch power on at power supply
Fig. 17
Entering Safety Obstruction Force Adjustment mode
•
Hinge open the Courtesy Lamp Cover to expose the adjustment controls.
•
Press and hold down the “Learn” Button (Figure.17) for two seconds - LED Indicator will commence a paused
double flash.
•
Safety Obstruction Force Adjustment can be carried out while LED Indicator is “paused double flashing”
•
To close out Safety Obstruction Force Adjustment Mode momentarily press “Learn” Button
Note: Mode will close out automatically after 10 minutes if not closed out manually beforehand
.
Safety Obstruction Force Adjustment – Open Direction
•
Hinge open the Lamp Cover to expose the adjustment controls
•
With the garage door in the fully closed position, press the black “Run” Button (Figure.17) so that the garage door
begins movement in the open direction
•
While the garage door is opening slowly, turn the (green) Open / Offset Adjustment Pin (Figure.17) in an
anti-clockwise direction until the garage door stops
•
Now turn the same pin clockwise five degrees
•
Refer to
‘Testing Safety Obstruction Force’
for testing
Safety Obstruction Force Adjustment – Close direction
•
With the garage door in the fully open position, press the black “Run” Button (Figure.17) so that the garage door
begins to close
•
While the garage door is closing, slowly turn the (red) Close / Speed Adjustment Pin (Figure.17) in an
anti-clockwise direction until the garage door stops and begins to Safety Reverse
•
Now turn the same pin clockwise five degrees
•
Refer to
‘Testing Safety Obstruction Force’
for testing
Содержание RDO II
Страница 1: ...1...
Страница 5: ...5 INSTALLATION MANUAL RDO Fig 1 Fig 2 Fig 2A Fig 3 Fig 3A...
Страница 23: ...23 INSTALLATION MANUAL RDO Notes...
Страница 24: ...24 INSTALLATION MANUAL RDO...