- 21 -
INSTALLATION MANUAL – RDO
Testing
•
Initiate a close cycle. As the garage door is closing interrupt the Safety Beams by passing an object through the
line of the Safety Beams. If the Safety Beams are functioning correctly the RDO II should stop and then
immediately reverse direction
•
If the garage door commences a close cycle reverses within one cycle, check that the Safety Beams are aligned
correctly as outlined in “Alignment”
Override
•
In the event of a Safety Beam malfunction the garage door can be closed by pressing and holding the black
“Run” Button (Figure.17) until such time as the garage door is fully closed and has stopped
•
Note:
If the black “Run” Button is released prior to the garage door reaching the fully closed position the RDO
II will Safety Reverse
13.10. Safety reverse
•
Partial Safety Reverse ensures that the garage door does not open fully and thereby present an unwanted security
risk
•
In the event that the garage door encounters a sufficient obstruction during a close cycle, the RDO II will
immediately stop and then begin to reverse direction, stopping after three seconds. In the event that a signal is
received immediately subsequent to partial Safety Reverse, the RDO II will recommence movement in the open
direction
13.11. Soft start
•
When commencing movement from any stationary position, the RDO II will slowly ramp up to full speed. This is
in order to minimise start-up load on the RDO II and garage door and provide smooth and quiet operation
13.12. Soft stop
•
By intelligently reducing the speed of the garage door as it approaches a limit point, the RDO II ensures quieter
garage door closing and prolonged RDO II and garage door life. (Standard function within Adaptive Mode only)
•
Adaptive Mode is factory configured to provide soft stopping prior to reaching a limit point. However, for garage
doors that are improperly-balanced it may be necessary to disable the soft stop function in order for the garage door
to fully close or fully open
•
Soft Stop is available only when Adaptive Mode has been selected
Enabling / Disabling
•
Remove the Courtesy Lamp and Control Box Covers to expose the Control Board
•
TO ENABLE – select Dipswitch No.5 (SS) to the “ON” position (Figure.20)
•
TO DISABLE – select Dipswitch No.5 (SS) to the “OFF” position (Figure.20)
•
Replace the Control Box and Courtesy Lamp Covers once selection has been completed
13.13. Speed control
•
Running speed may be adjusted within the range of 70 ~ 100% of maximum speed
•
Note:
Available only when Adaptive Mode has been selected
Adjustment
•
To enter Speed Control adjustment mode;
•
Move the Drive Unit so that it is positioned midway between the two Limit Adjust Prongs
•
Hinge open the Courtesy Lamp Cover to expose the adjustment controls (Figure.18)
•
Press and hold the “Learn” Button (Figure. 17) for two seconds in order to initiate Forced Learn – LED
Indicator will begin to quick flash
•
Rotate the (red) “Speed” Adjustment Pin (Figure.17) in a clockwise direction to increase running speed and
anti-clockwise to decrease running speed
•
Close the Courtesy Lamp cover once adjustment has been completed
•
Running speed may only be adjusted while the Drive Unit is travelling between Limit Points
•
Speed Control adjustment will close out automatically once the Drive Unit reaches either one of the Limit
Adjust Prongs