Temperature (configuration hidraulic crossover or accumulation tank)
CONFIGURATION 11 - (CRO / BUF) (used only in cascades and external start)
80°C
120°C
0%
1700
15k
30%
60°C
60°C
3
bar
2
4
5
P1
6b
7
8
1
M
3
M
bar
2
4
5
P1
1
9
6a
80°C
120°C
0%
1700
15k
30%
60°C
70°C
50°C
When ‘’1 Temperature’’ is selected, screen shows hydraulic crossover with 1 temperature.
If
‘’2 Temperatures’’ is
selected, screen shows accumulation tank with 2 temperatures.
This option can be changed only by authorized serviceman.
10.1.2 temp displays
2 Temperatures
Factory:
1 Temperature
1 Temperature
2 Temperatures
10.1.2 temp. displays
2 Temperatures
Factory:
1 Temperature
2 Temperatures
1 Temperature
Scheme of configuration
On the screen
Scheme 11.
Configuration
CRO / BUF
Version 1: (display shows 1 temperature, eg. hidraulic crossover)
Version 2: (Display shows 2 temperatures (eg. accumulation tank)
1 - Boiler PelTec / PelTec-lambda
2 - Air self-venting group 2,5 bar
3 - Motor 4-ways mixing valve
4 - Closed type expansion vessel
5 - Return flow temperature sensor
6a - Hydraulic crossover
6b - Accumulation tank
7 - Accumulation tank sensor 1 (upper)
8 - Accumulation tank sensor 2 (lower)
9 - Hydraulic crossover sensor
Connecting the temp. sensor 9 (version 1) and temp. sensors 7, 8 (version 2) is not required for operation of the boiler.
These temperatures are only informative, only to see the temperatures and they don't affect boiler operation. If temp.
sensors are not connected, regulation will show temperature " - °C". The boiler regulation will not report any error even if
the sensors are or defective.
34
Technical instructions REGULATION
PelTec / PelTec-lambda
NOTES:
- In this configuration is possible to upgrade up to 4 unit "CM2K-P module for regulation 2 heating circuits“.
- In this configuration is possible to connect external control (external start).