Temperature
(
accumulation tank
--indire
ct heating circuit)
2. TEMPERATURE (CONFIGURATION BUF
--I
HC)
2. Temperature
Diff. buf. tank temp.
3.
Buffer tank temp.
Min buf.tank temp
1.
2.
default: 80°C
Minimum: 40°C
Maksimum: 85°C
The possibility of setting the desired temperature of the accumulation tank.
2.1 TEMPERATURE OF THE ACCUMULATION TANK
default: 20°C
Minimum: 5°C
Maksimum: 64°C
The possibility of setting the minimum temperature of the accumulation tank.
2.2 MINIMUM TEMPERATURE OF THE ACCUMULATION TANK
default: 10°C
Minimum: 5°C
Maksimum: 30°C
The possibility of setting the accumulation tank difference.
2.3 ACCUMULATION TANK DIFFERENCE
Possible selection:
Possible selection:
Possible selection:
22
Technical instructions REGULATION
PelTec / PelTec-lambda