7. Once the Suction line is attached to the evaporator, slide the 4” tube insulation
sleeve so that it covers the metal connections that were just installed and one
end is flush to the unit housing. Use two tie wraps to secure the insulation in
place. If you forgot to pre-install the insulation sleeve before making the suction
line connection to the evaporator, it is acceptable to slit the insulation and wrap
around the coupling, provided that the seam is sealed tight. Insulating the
suction connection is essential to avoid condensation issues.
8. Identify the Liquid line (marked RED on the female connector). This line is not
insulated.
9. Identify the male Liquid line connection on the rear or optional left side of the
evaporator (marked RED on the male connector), and attach the female Liquid
line connection. To the male connection.
STOP AND MAKE SURE YOU ARE
ATTACHING RED TO RED.
Follow the same process to tighten the
connection.
3000/4000Sqc‐EC Liquid
Rear Connection
(Red)
3000/4000Shqc‐EC Liquid
Rear Connection
(Red)