If the cooling unit runs too much, you can raise the Minimum Set Point to reduce the 
cycle “on” time. Most wine collectors store their wine in the range of 55 - 60°F. 

CellarPro  cooling  units  are  designed  to  maintain  appropriate  levels  of  humidity, 
ranging  from  50  to  70  percent,  inside  wine  cellars.  In  order  to  increase  or  decrease 
humidity  inside  the  cellar,  the 

Fon

  setting  can  be  changed  as  described  in  the 

“Advanced Operation” section later in this chapter. 

Switch Instructions 

 

(1)  Control  Panel:    Maintains  desired  cellar  environment.    Factory  settings  are 
optimized  for  peak  performance.  Controller  is  described  in  detail  in  the  following 
section. 

(2)  Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3 
speed settings: Low, Medium, and High.  For optimum sound and energy efficiency, 
select the lowest fan speed that will maintain the desired cellar temperature.  High 
speed is recommended for initial cellar pull down, 

extreme

 temperature conditions 

and ducted installations. 

(3)    Bottle  Probe  Jack  (Bottle  Probe):    Plug  in  the  remote  bottle  probe  (sold 
separately)  to  control  the  cellar  by  liquid  temperature  rather  than  air  temperature 
inside the cellar.  Disconnecting the probe will automatically return the control to air 
temperature. When using a bottle probe, the 

Temperature Differential

 will need to 

be adjusted to 1 as shown in the “Advanced Operation” instructions below.

 

 

 

 

Содержание 3000Shqc-EC

Страница 1: ...V3 15 22 ControltheElements QuickConnectSplitRefrigerationSystems Owner sManual...

Страница 2: ...2 V3 15 22 This page intentionally left blank...

Страница 3: ...f you still have questions please don t hesitate to contact your dealer or reach us directly at CellarPro Cooling Systems 1445 N McDowell Blvd Petaluma CA 94954 707 794 8000 x3 Email info cellarprocoo...

Страница 4: ...b l e o f C o n t e n t s I Package Contents 5 II Specifications and Cut Sheets 6 III Cellar Construction 9 IV Installation Instructions 11 V Operating Instructions 26 VI Troubleshooting 33 VII Limit...

Страница 5: ...sleeve 1 1 Butyl 18 in n a Adhesive backed foam strips 1 x 9 25 x1 5 x1 5 and 1 x 3 75 x1 5 x1 5 n a 1 Set Large tie wraps 2 2 Remote Display Kit 1 optional 1 optional Bottle Probe 1 optional 1 optio...

Страница 6: ...mounting bracket 63 0 50 5 6 4000Shqc EC 30 4 x 14 4 x 13 2 incl mounting bracket 65 0 50 7 9 Condensing Unit with Hood Model Dimensions W x D x H inches Weight lbs MCA 3000Sqc Shqc EC 19 4 x 23 3 x...

Страница 7: ...7 V3 15 22 Evaporator Cut Sheets...

Страница 8: ...8 V3 15 22 Condensing Unit Cut Sheet...

Страница 9: ...er recessed lighting which can allow air to leak into the cellar It is important that all walls joints doors and windows electrical outlets and or switches pipes vents and light fixtures be sealed to...

Страница 10: ...o the bottom of the cellar To ensure proper airflow and reduce temperature stratification inside the cellar the space in front of the cold air discharge should be clear of any obstructions including w...

Страница 11: ...r warranty does not cover damage from marine exposure within 5 miles of the ocean In these environments you will need an applied coating such as Insitu to protect against corrosion that is common in c...

Страница 12: ...ns 3000Sqc EC and 4000Sqc EC Connection locations are specified when ordering the equipment and are available in the following options Refrigerant connections rear or left side Power cord rear or left...

Страница 13: ...Shqc EC and 4000Shqc EC Connection locations are specified when ordering the equipment and are available in the following options Refrigerant connections rear or left side Power cord rear or left side...

Страница 14: ...V3 15 22 Evaporator Mounting Instructions 3000Sqc EC and 4000Sqc EC Mounting brackets which attach to the sides of the evaporator are provided to mount the evaporator flush to a wall inside the cella...

Страница 15: ...ches to the wall behind the evaporator is provided to mount the evaporators to the wall inside the cellar First the wall bracket is attached to the wall and then the evaporator slides onto the bracket...

Страница 16: ...again into an open drain Then fill the trap with water The condensate trap will allow any excess moisture inside the Evaporator to overcome the static pressure and flow out of the drain line Before pu...

Страница 17: ...he Condensing Unit turns on and off based on suction pressure as follows The Evaporator includes a factory installed liquid line solenoid valve LLSV which is controlled by the Evaporator temperature c...

Страница 18: ...18 V3 15 22 Wiring Diagram...

Страница 19: ...QuickConnect Line Set has sufficient length to interconnect the two units If the line set is not long enough do not proceed Contact CellarPro for immediate assistance 2 Reference the Evaporator Mount...

Страница 20: ...tion line connection to the male connection STOP AND MAKE SURE YOU ARE ATTACHING BLUE TO BLUE Hand thread at first to get the threads started without cross threading Once it is too hard to turn by han...

Страница 21: ...d wrap around the coupling provided that the seam is sealed tight Insulating the suction connection is essential to avoid condensation issues 8 Identify the Liquid line marked RED on the female connec...

Страница 22: ...nnections only It is important to keep the drain line level or below the point where it exits the evaporator as it passes through the cutout 11 3000Sqc EC 4000Sqc EC systems rear connections only Appl...

Страница 23: ...o the wall cutout and drywall trim around the connections as desired For serviceability do not use spray foam to insulate around the metal QuickConnect fittings 16 Route the drain line installing a tr...

Страница 24: ...onnection STOP AND MAKE SURE YOU ARE ATTACHING BLUE TO BLUE Follow the previous process to tighten the connection 22 Identify the Liquid line marked RED on the female connector 23 Identify the male Li...

Страница 25: ...nsing unit fans to confirm airflow There shouldn t be any excessive vibration noise or obstructions to airflow Do not leave the system unattended until it has reached normal operating conditions and t...

Страница 26: ...wine which tend to be much colder than storage temperatures especially serving temperatures for white and sparkling wines CellarPro cooling units must be used stored moved and or shipped in the uprigh...

Страница 27: ...ontroller is described in detail in the following section 2 Fan Speed Selector Switch Low Med High The cooling unit fans operate on 3 speed settings Low Medium and High For optimum sound and energy ef...

Страница 28: ...grill of the cooling unit Power On Off Press Power On Off to turn the unit on and off When the Compressor On indicator light is on the Compressor is running When the Fan On indicator light is on the F...

Страница 29: ...Differential of 4 F This means that the cooling unit will turn on when the display rises above 62 F 58 F 4 F and turn off when the display falls below 58 F In this example the average temperature ins...

Страница 30: ...re Differential is unchanged Quick Chill Button To activate the Quick Chill mode press the Up Quick Chill button for three seconds To deactivate Quick Chill press Quick Chill button for three seconds...

Страница 31: ...To activate the Quick Chill mode press the Up button for 3 seconds To deactivate Quick Chill press the Up button for 3 seconds again The Quick Chill indicator Row 3 light will turn on when the cooling...

Страница 32: ...ry preset ENERGY SAVINGS MODE DIFFERENTIAL The factory preset for this setting is 4 This setting controls the Temperature Differential for the Energy Savings Mode The recommended range for this settin...

Страница 33: ...lter is clean 3 Increase the supply of cool air to the space outside the condenser coils using a fan ducting or an exhaust system to remove heat from the space 4 Raise the Minimum Set Point on the coo...

Страница 34: ...eck for loose wires and reconnect Low pressure switch is open On Valve control systems make sure solenoid is energized Jumper out switch to check for a faulty switch and replace if necessary Note that...

Страница 35: ...re power Power supply to fan interrupted loose wire Inspect for loose fan wiring and reconnect Fan capacitor check for loose wires or out of spec capacitance Reconnect loose wires or replace capacitor...

Страница 36: ...op section Condensing unit never shuts off System is wired incorrectly Locate correct wiring diagram for Electronic or Valve controlled system trace wiring and correct If a Valve control system the lo...

Страница 37: ...first 23 hours of operation after the cooling unit is plugged in and or turned on The control panel also will flash a code for each alarm as follows Alarm What it means What to do P1 Probe 1 which sen...

Страница 38: ...ted warranty applies only to cooling units purchased from the factory or an authorized dealer Damage caused by others or by any cause beyond the control of CellarPro shall not be considered defects in...

Отзывы: