CellarMate Manual
Page 2
Accessories and Optional Equipment
Heating Coils
The optional heating coil is built-in and requires no additional power source. The electric
heating option is factory installed and includes primary and secondary over-temperature
protection devices per UL and NEC. It is located between the evaporator coil and the blower
inside the transition duct. It contains the heating element and high-temperature limit
switches. The heating coil is wired to work in conjunction with the thermostat. Since the
thermostat prevents the heating and cooling circuits from being on at the same time, no
additional power wiring is needed. Set the auto mode on the thermostat so it can
automatically switch from heating to cooling
No maintenance is required for the heating coil. To test the heating coil operation, set the
thermostat on heat and set the temperature above the cellar temperature. The supply air
temperature should rise above the return air.
Water Cooled
A water-cooled option is available that uses a tube-in tube heat exchanger in place of the
condenser coil and fan. Waste heat from the refrigerant is transferred to the water. A control
valvue is used to regulate the flow of water to maintain head pressure. Leaving water is
clean and acceptable for other applications. (This option available for the 025 model in the
second quarter of 2005).
Duct Collars, Flexible Ducting, and Accessory Kits
Duct Collars
Duct collar adaptors are mounted on either a large panel (21”x12”) or a medium panel
(12”x12”), and come in two diameters; 10” for the CM050, CM088, and CM200, and
8” for the CM025. The duct collar adaptors replace the removable solid panels on the
unit. (Refer to the Air Flow Illustration on page 8 8 for panel locations, and Ppanel
sSizes on Page 215.)
Flexible Ducting
The flexible ducting is a 25’ foot length of 10” insulated ducting for the CM050,
CM088, and CM200 and 8” insulated ducting for the CM025.
Accessory Kits
An accessory kit consists of two duct collar adaptors (one of each size panel) and one
25’ length of flexible ducting. Accessory kits come in both 10” and 8” diameters.
Low Ambient Option
A factory installed Low Ambient Option (LAO) is available which makes the CellarMate
capable of exposure to low ambient temperatures. This feature controls the condenser fan
operation based on head pressure and heats the oil reservoir. The LAO is recommended
whenever the condenser section is exposed to air temperatures below 40°F.
Содержание Wine Cellar Climate Control
Страница 1: ...CellarMate The Key to Wine Cellar Climate Control Installation Operation and Maintenance Manual...
Страница 11: ...CellarMate Manual Page 6...
Страница 26: ...CellarMate Manual Page 21 Dimensions and Components and Components...
Страница 27: ...CellarMate Manual Page 22 Performance and Specifications...
Страница 29: ...CellarMate Manual Page 24 Ducting Options...
Страница 30: ...CellarMate Manual Page 25 Single Outlet Duct Installation Dual Outlet Duct Installation...
Страница 31: ...CellarMate Manual Page 26 Wiring Diagram Models 025 and 050...
Страница 32: ...CellarMate Manual Page 27 Wiring Diagram Models 088 and 200...
Страница 33: ...CellarMate Manual Page 28 Wiring Diagram Humidifier...