background image

1. From menu 

Configuration 

select 

Users,

2. In section 

Configure Users

, select added user eg. 

admin

,

3. Will open the page 

User Configuration

 – admin, where are sections:

A/ 

User Configuration 

– possibility of rename user and password,

B/ 

User Access

 - method of access to converter from the network:

Allow command line access

 – access using the Command Line Interface - 

telnet

,

Allow web interface access

 – access using the internet browser. 

C/ 

User Permissions - 

user permissions to configuration and management of the ADA-13040MG converter, where are options:

None

 - no permission,

Read - 

permission to read,

Read Self - 

permission to read own settings, but not other users.

Read/Write 

- full permission to read and write the setting.

Read/Write Self - 

permission to read and write own setting, but not other users.

Read All/Write Self - 

permission to read the setting for all users and modify only own setting (not other users).

Execute - 

permission to execute (start). 

4. All changes are saved by pressing 

[Apply]

.

5.2.5. MANAGEMENT

In menu 

Management

 are two options:

Serial Ports

Connections

5.2.5.1. SERIAL PORT MANAGEMENT

Section 

Serial Ports

 allows to identification connections/disconnection to the serial port of the converter through the network.

5.2.5.2. CONNECTIONS MANAGEMENT

Section 

Connections

 allows to identification connections/disconnection to the converter through the network.

5.2.6. ADMINISTRATION

The menu 

Administration

 allows : 

to delete/upload files with Java applet, 

to backup/restore configuration of converter,

to update Firmware,

to restore the factory default settings,

to display system details information,

to reboot the converter.

5.2.6.1. FILE MANAGEMENT

Section

  File Management

  enables upload and delete Web provided by manufacturer. Uploaded index.htm or index.html allows to

automatically run the page in the web browser after entering  

http://address-ip-convertera/FS/WEB/index.htm

 

and login to

 

ADA-

13020.

5.2.6.2. BACKUP & RESTORE CONFIGURATION 

Section

 Backup/Restore

 enables backup to file or restore from file the user configuration of the converter.

5.2.6.3. FIRMWARE UPDATE

Section

 Update Firmware

 enables to make the update firmware from the file. Firstly should be done update the POST software before

updating the firmware – more details available on the web page 

http://www.cel-mar.pl

.

5.2.6.4. FACTORY DEFAULT SETTINGS

The converter was configured by the manufacturer. 
To restore factory default settings, select from menu 

Factory Default Settings

. After that the converter will automatically reboot.

5.2.6.5. SYSTEM INFORMATION

Section 

System Information

 displays:

General

 – device model, MAC address, firmware version, Boot version, POST version and more.

GPIO

 – not applicable in ADA-13020.

Serial

 – port description, current settings of serial port, status of controlling lines and the statistics data transfer through the serial

port.

Network

 – show statistics of ETHERNET interface for IP, TCP, UDP, ICM protocols.

5.2.6.6. REBOOT

Section

 Reboot

 allows making software reset of ADA-13020. Pressing [

Reboot

] will start rebooting of server during 1 min.

5.2.6.7. LOGOUT – ENDING MANAGEMENT AND CONFIGURATION

After completion of the configuration or administration should be pressing  

Logout

 on left panel – logout from www server of ADA-

13020 converter.

22

ADA-13020

Содержание ADA-13020

Страница 1: ...User manual ADA 13020 ETHERNET to Current Loop Converter 1 io_ada 13020_v1 14_en ADA 13020 Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...ORK SETTING 13 5 2 CONFIGURATION AND MANAGEMENT BY THE USE OF INTERNET BROWSER 15 5 2 1 NETWORK SETTING CONFIGURATION 15 5 2 2 SERIAL PORT CONFIGURATION 16 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION OP...

Страница 3: ...6 2 REALPORT CONFIGURATION IN WINDOWS XP 23 7 FACTORY DEFAULT 25 8 TROUBLESHOOTING 25 9 VERSIONS 25 10 SPECIFICATION 26 3 ADA 13020...

Страница 4: ...network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the devic...

Страница 5: ...ade on base safety diodes and fuses on each Current Loop lines To Current Loop interface can be connected one device in point to point topology operates in half duplex or full duplex mode This convert...

Страница 6: ...CURRENT LOOP TRANSMITTER The Current Loop transmitter at ADA 13020 is made as active on the base power source generate current depend on converter s version 20mA or 0 20mA TTY The transmitter has a sh...

Страница 7: ...ll the device on TS 35 should be the upper part of the casing put hooks on the terminal and then press the bottom of the cover until you hear a characteristic Click sound 3 2 ETHERNET NETWORK CONNECTI...

Страница 8: ...OF PC If there is not the switch or the HUB it is possible to connect the ADA 13020 directly to a network adapter of PC using the cross over cable Table 2 This connection can be used for converter co...

Страница 9: ...8 Connecting for functioning in TCP UDP serial bridge mode one to one in LAN network 9 ADA 13020 ROUTER Public IP address ETHERNET Straight cable Tabela 1 ETHERNET Straight cable Tabela 1 Current Loop...

Страница 10: ...device with active transmitter passive receiver 10 ADA 13020 Current Loop Current Loop Current Loop ADA 13020 Static IP address SLAVE Device with Device with Current Loop interface interface ADA 1302...

Страница 11: ...the Current Loop BUS like on the picture below In this case Current Loop bus is created by eg one converter ADA 13020 1 1 2 2 3 MASTER Active Transmitter one converter ADA 1020 1 1 2 2 3 SLAVE Active...

Страница 12: ...otection from opposite connection power supply 12 ADA 13020 SLAVE 2 RS232 SLAVE 15 RS232 ADA 1020 1 2 2 3 SLAVE PASSIVE 1 SLAVE 1 RS232 RS232 Rx Rx Rx Tx Tx DB 9F RS232 connector Rx Rx Rx Tx Tx DB 9F...

Страница 13: ...AWiz are available in Start Programs CEL MAR ADANet 5 1 2 NETWORK SETTING The ADAFinder is use for configuration of converter s network setting Before running the ADAFinder should be disabled the Syst...

Страница 14: ...Fig 14 Basic network configuration Fig 15 IP address setting 14 ADA 13020...

Страница 15: ...ow Fig 16 Page for manage and configuration of ADA 13020 converter 5 2 1 NETWORK SETTING CONFIGURATION To make changes of default setting or new configuration of ADA 13020 select on left panel Configu...

Страница 16: ...erial Port Configuration select Port 1 will open the configuration details page includes Port Profile Settings Basic Serial Settings Advanced Serial Settings 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION...

Страница 17: ...5 2 2 1 2 TCP SOCKETS CONFIGURATION Choosing TCP Sockets is configured the serial port of ADA 13020 for direct communication with PC by the use of TCP socked Data sending by application to TCP socked...

Страница 18: ...e is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client service...

Страница 19: ...ofile will open section UDP Server Settings with operating parameters like on picture below Set access to UDP server on e g 2101 port Then select Automatically send serial data in section UDP Client S...

Страница 20: ...working UDP Server of converter connected to MASTER device and press Add In the section Send data under any of the following conditions is recommended to set parameters like on picture bellow For sav...

Страница 21: ...ts Parity Stop Bits the same parameter like has device connected to the serial port of the converter 5 2 3 SYSTEM SETTINGS Select on left panel menu Configuration System and then on right will be sele...

Страница 22: ...tore the factory default settings to display system details information to reboot the converter 5 2 6 1 FILE MANAGEMENT Section File Management enables upload and delete Web provided by manufacturer U...

Страница 23: ...Open 6 when the installation window will appear press Next 7 will start the searching for converters in the network 8 if no devices were not found press Next 9 should be set in the window Describe the...

Страница 24: ...Fig 24 Device view on Windows XP Fig 25 Example configuration of multi port serial adapter 24 ADA 13020...

Страница 25: ...ec when the converter will start with default settings Restoring Default Settings deletes existing configuration and the proper configuration should be loaded to the converter from the backup I change...

Страница 26: ...nalization PWD green LED power supply RX red LED data reception on Current Loop port TX yellow LED data transmission via Current Loop port Electrical Parameters Power requirements 10 24 30 V DC Power...

Страница 27: ...27 ADA 13020...

Страница 28: ...a transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you...

Отзывы: