Fig 18. The page with serial port profiles
5.2.2.1.1. REALPORT (VIRTUAL PORT ) CONFIGURATION
Choosing
RealPort
(Virtual Port, Fig. 18), is configured the serial port of ADA-13020, for communication with virtual port COM of
computer. Press [
Apply
] for save. After installation driver (RealPort) of virtual port COM (see chapter 6) in operating system, data
sending by application to this port are transferred through WLAN/WAN to ADA-13020 converter and are present on his serial port. The
driver
RealPort
installation is presented in chapter 6. Normally
RealPort
service allows for one connection through WLAN/WAN,
between computer and server port.
Connection from other computers to the converter will be not taken, what will cause the error message.
5.2.2.1.2. TCP SOCKETS CONFIGURATION
Choosing
TCP Sockets,
is configured the serial port of ADA-13020, for direct communication with PC by the use of TCP socked. Data
sending by application to TCP socked are transferred through network to ADA-13020 converter and are present on his serial port. To
save selected configuration, press the button [
Apply
].
5.2.2.1.2.1. TCP SERVER AND CLIENT CONFIGURATION
After saving the TCP Sockets profile, will open section
TCP Server Settings
(picture below), includes configuration of:
–
port for Telnet service; standard 2001,
–
port for serial port service; standard 2101 (through this port are transferred data to serial port of converter),
–
port for security access to serial port service; standard 2601 (through this port are transferred data to serial port of converter),
and possibility of selection
Enable TCP Keep Alive
– connection will be kept, even if the data is not transmitted over the network.
17
ADA-13020