Order example:

Product symbol: 

ADA-13020-1-1-1-2-3

1

 

– 

basic electronic version,

1 – 

 current loop voltage 24VDC,

1 – 

current loop type ± 20mA,

2 – 

galvanic isolation 1kV=,

3 – 

cover without inlets, plug-in screw terminal block.

10. SPECIFICATION

TECHNICAL DATA

Transmission Parameters

Net/ Interface

ETHERNET

Current Loop

Connector

RJ45

Screw terminal, max. wire Ø 2,5mm

2

.

Line length

LAN up to 150 m

Depend on baud rate up to few hundred

meters

Max. number of connected device

Depend on addressing type in network

2 point-to-point or 15 in Current Loop

network

Max. baud rate

10/100 Mbit/s

38,4 kbps (depend on  length Current Loop

line)

Transmission line

4-pair

 

twisted

 

cable,

 

UTP

4x2x0,5(24AWG),   shield   inside   large

interferences (STP 4x2x0,5(24AWG))

2-pair twisted cable, UTP Nx2x0,5(24AWG),

shield   inside   large   interferences   (STP

Nx2x0,5(24AWG))

Standards

IEEE 802.3

0-20mA(TTY), +/-20mA

Transmission type 

Asynchronism half duplex or full duplex,

Optical Signalization

PWD – green LED (power supply)

RX - red LED data reception on Current Loop port,

TX - yellow LED data transmission  via Current Loop port,

Electrical Parameters

Power requirements

10 - 24 – 30 V DC

Power Cable

Recommended length of  power cable – up to 3m

Power

3W

Protection from reverse power polarization

YES

Galvanic Isolation

1kV= or 3kV= (between power circuit and  ETHERNET signal line)

1kV= or 3kV= (between power circuit and Current Loop signal line)

Optoisolation

~3kV= (between signal lines Current Loop and ETHERNET)

Electromagnetic compatibility

Resistance to disruptions  PN-EN 55024.

Emission of disruptions PN-EN 55022.

Safety requiring

According to the PN-EN60950 norm.

Environment

Commercial and light industrial.

Environmental Parameters

Operating temperature

-30 ÷ 60°C

Humidity

5 ÷ 95% - non-condensing

Storage temperature

-40 ÷ 70°C

Casing

Dimensions

53mm x 90mm x 62mm,

Material

Noryl UL. 94 V-O

Degree of casing protection

IP40

Degree of terminal protection

IP20

Weight

0,10 kg

According to standards

DIN EN50022, DIN EN43880

Location during work

Free

Mounting method

On the rail compliant with DIN35 / TS35 standard.

26

ADA-13020

Содержание ADA-13020

Страница 1: ...User manual ADA 13020 ETHERNET to Current Loop Converter 1 io_ada 13020_v1 14_en ADA 13020 Copyright 2001 2017 CEL MAR sp j...

Страница 2: ...ORK SETTING 13 5 2 CONFIGURATION AND MANAGEMENT BY THE USE OF INTERNET BROWSER 15 5 2 1 NETWORK SETTING CONFIGURATION 15 5 2 2 SERIAL PORT CONFIGURATION 16 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION OP...

Страница 3: ...6 2 REALPORT CONFIGURATION IN WINDOWS XP 23 7 FACTORY DEFAULT 25 8 TROUBLESHOOTING 25 9 VERSIONS 25 10 SPECIFICATION 26 3 ADA 13020...

Страница 4: ...network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the devic...

Страница 5: ...ade on base safety diodes and fuses on each Current Loop lines To Current Loop interface can be connected one device in point to point topology operates in half duplex or full duplex mode This convert...

Страница 6: ...CURRENT LOOP TRANSMITTER The Current Loop transmitter at ADA 13020 is made as active on the base power source generate current depend on converter s version 20mA or 0 20mA TTY The transmitter has a sh...

Страница 7: ...ll the device on TS 35 should be the upper part of the casing put hooks on the terminal and then press the bottom of the cover until you hear a characteristic Click sound 3 2 ETHERNET NETWORK CONNECTI...

Страница 8: ...OF PC If there is not the switch or the HUB it is possible to connect the ADA 13020 directly to a network adapter of PC using the cross over cable Table 2 This connection can be used for converter co...

Страница 9: ...8 Connecting for functioning in TCP UDP serial bridge mode one to one in LAN network 9 ADA 13020 ROUTER Public IP address ETHERNET Straight cable Tabela 1 ETHERNET Straight cable Tabela 1 Current Loop...

Страница 10: ...device with active transmitter passive receiver 10 ADA 13020 Current Loop Current Loop Current Loop ADA 13020 Static IP address SLAVE Device with Device with Current Loop interface interface ADA 1302...

Страница 11: ...the Current Loop BUS like on the picture below In this case Current Loop bus is created by eg one converter ADA 13020 1 1 2 2 3 MASTER Active Transmitter one converter ADA 1020 1 1 2 2 3 SLAVE Active...

Страница 12: ...otection from opposite connection power supply 12 ADA 13020 SLAVE 2 RS232 SLAVE 15 RS232 ADA 1020 1 2 2 3 SLAVE PASSIVE 1 SLAVE 1 RS232 RS232 Rx Rx Rx Tx Tx DB 9F RS232 connector Rx Rx Rx Tx Tx DB 9F...

Страница 13: ...AWiz are available in Start Programs CEL MAR ADANet 5 1 2 NETWORK SETTING The ADAFinder is use for configuration of converter s network setting Before running the ADAFinder should be disabled the Syst...

Страница 14: ...Fig 14 Basic network configuration Fig 15 IP address setting 14 ADA 13020...

Страница 15: ...ow Fig 16 Page for manage and configuration of ADA 13020 converter 5 2 1 NETWORK SETTING CONFIGURATION To make changes of default setting or new configuration of ADA 13020 select on left panel Configu...

Страница 16: ...erial Port Configuration select Port 1 will open the configuration details page includes Port Profile Settings Basic Serial Settings Advanced Serial Settings 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION...

Страница 17: ...5 2 2 1 2 TCP SOCKETS CONFIGURATION Choosing TCP Sockets is configured the serial port of ADA 13020 for direct communication with PC by the use of TCP socked Data sending by application to TCP socked...

Страница 18: ...e is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client service...

Страница 19: ...ofile will open section UDP Server Settings with operating parameters like on picture below Set access to UDP server on e g 2101 port Then select Automatically send serial data in section UDP Client S...

Страница 20: ...working UDP Server of converter connected to MASTER device and press Add In the section Send data under any of the following conditions is recommended to set parameters like on picture bellow For sav...

Страница 21: ...ts Parity Stop Bits the same parameter like has device connected to the serial port of the converter 5 2 3 SYSTEM SETTINGS Select on left panel menu Configuration System and then on right will be sele...

Страница 22: ...tore the factory default settings to display system details information to reboot the converter 5 2 6 1 FILE MANAGEMENT Section File Management enables upload and delete Web provided by manufacturer U...

Страница 23: ...Open 6 when the installation window will appear press Next 7 will start the searching for converters in the network 8 if no devices were not found press Next 9 should be set in the window Describe the...

Страница 24: ...Fig 24 Device view on Windows XP Fig 25 Example configuration of multi port serial adapter 24 ADA 13020...

Страница 25: ...ec when the converter will start with default settings Restoring Default Settings deletes existing configuration and the proper configuration should be loaded to the converter from the backup I change...

Страница 26: ...nalization PWD green LED power supply RX red LED data reception on Current Loop port TX yellow LED data transmission via Current Loop port Electrical Parameters Power requirements 10 24 30 V DC Power...

Страница 27: ...27 ADA 13020...

Страница 28: ...a transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you...

Отзывы: