background image

NHT UL AF BL

12

Ugolini spa

1 INTRODUCTION

This operator’s manual is a complement to the standard
Granita machine operator’s manual available in the unit
package.
Carefully read first the standard unit Operator’s Manual and
then all the following sections of this one thoroughly to
familiarize yourself with all aspects of the system.
The purpose of the Autofill Device is to increase the
productivity of a Granita Machine far beyond the containers
capacity, allowing the automatic refill as soon as the product in
the containers drops lower a preset level.
In order to operate a Granita Machine equipped with Autofill
Devices a remote fill system is required.
The remote fill system is composed of all those parts that are
installed outside the dispenser and is intended to supply the
dispenser with the adequate and correct beverage to be
frozen.
It is not the aim of this manual to instruct about how to set up
and operate a remote fill system. To get more information
about that please make reference to our “Autofill System for
Granita Machines - General description and typical installation
flow charts”.

2 INSTALLATION

1 - Loosen the fitting locker located on the rear cover of each

bowl equipped with Autofill Device and connect the remote
fill system using a 1/4” fitting suitable to the purpose.
Tighten the fitting locker.

2 - On the lower rear panel of the machine a 6-pole terminal

block is located. It is designed for connecting some
accessories such as a Safety Water Line Solenoid Valve
and one Sold-out Switch each bowl (see figure 1).

figure 1

3 - The Safety Water Line Solenoid Valve is intended to cut off

the main water line (if present in the remote fill system)
whenever the Autofill Device is not refilling.
The Sold-out Switch (one for each bowl) disables the
Autofill Device and activates acoustic and visual alarms
whenever the incoming beverage is sold out.
The Safety Water Line Solenoid Valve, if present, must be
connected to the unit using  #1 and  #2 poles of the
terminal block (see figure 1).

If a Safety Water Line Solenoid Valve is not used do not
use  #1 and  #2 poles.
If the remote fill system is equipped with Sold-out switches
connect their wires to #3 and #4 poles (for one bowl unit),
to  #3, #4 and #5 poles (for two bowls unit) and to #3, #4,
#5 and #6 poles (for three bowls unit) as per figure 1
diagram.

4 - The Autofill Device doesn’t come presanitized from the

factory. Prior to starting operation an In-Place Sanitization
is  t o  b e  pe r f or m e d  ac c o r d in g  w it h  t hi s   ha n d bo o k
instructions (paragraph 3.3 IN-PLACE SANITIZATION).

3 OPERATING PROCEDURES

Once the remote fill system is set up, follow the procedures
described in chapter 3.1 DESCRIPTION OF CONTROLS to
activate the Autofill system.

If the clip probe is properly installed and the bowl properly fitted
in their position, the remote fill system starts to operate and
feed the bowl through the hole in the rear wall. As soon as the
product level reaches the lowest tip of the probe, the priming
automatically stops. 
As soon as the probe tip immersed in the product gets
uncovered (because of dispensed product), the solenoid valve
inside the rear wall automatically opens and fresh beverage
flows into the bowl until the probe tip gets covered again.
The solenoid valve opening occurs with about 10 seconds
delay to avoid that the irregular waving of product surface,
occasionally discovering probe tip, may be understood as level
dropping “cause of dispensing”.
A sold-out warning light along with a buzzer (visual and
acoustic sold-out alarms) are located respectively on and
inside the rear cover. They can run only if an applicable Sold-
out switch is connected to the terminal block (see figure 1).

3. 1 DESCRIPTION OF CONTROLS

Each Autofill Device is equipped with a three position switch

IMPORTANT

Whatever the remote fill system may be make sure that
the inlet product pressure into the Autofill Device is not
exceeding 2.5 bar (36 psi).

IMPORTANT

Safety Water Line Solenoid Valve must be 24V DC 12W
maximum.

IMPORTANT

If no Sold-out switch is used make sure that 

#

3, 

#

4, 

#

5

and 

#

6 poles on the terminal block are connected

together.

IMPORTANT

The device is designed so as no refilling occurs in case
either the clip probe is not properly installed or the bowl
not properly fitted.

Содержание NHT-1P-UL

Страница 1: ...O P E R A T O R S M A N U A L MANUAL DE INSTRUCCIONES NHT UL AF ENGLISH ENGLISH ESPA OL B L A C K...

Страница 2: ......

Страница 3: ...7 5 3 2 CLEANING 8 5 3 3 SANITIZING 9 5 3 4 ASSEMBLY 9 5 4 IN PLACE SANITIZATION 10 5 5 REAR SEAL MAINTENANCE 10 6 ROUTINE MAINTENANCE 10 6 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSON...

Страница 4: ...0 60 Hz areas applications Should you prefer to connect the unit directly to the mains connect the supply cord to a 2 pole wall breaker whose contact opening is at least 3 mm Do not use extension cord...

Страница 5: ...d a light switch In addition each bowl is individually operated by a mixer refrigeration switch In fact it is possible to dispense both soft drinks and Granita When a bowl is in Soft Drink mode the be...

Страница 6: ...be refilled after the product level drops lower than half of the evaporator cylinder and at the start of each day 7 For good product conservation the dispenser must run overnight at least in Soft Dri...

Страница 7: ...I position set mixer refrigeration switch es to I position Soft Drink mode place a pail under each faucet and drain all product from bowls set all control switches to the 0 position 5 3 1 DISASSEMBLY...

Страница 8: ...l soap 2 Prepare at least two gallons of a warm 45 60 C 120 140 F sanitizing solution 100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with half a gallon of water acco...

Страница 9: ...the gasket and its front fastening hooks are properly engaged see figure 15 figure 15 8 Use fresh product to chase any remaining sanitizer from the bottom of the bowl s Drain this solution Do not rin...

Страница 10: ...it or switch off the 2 pole wall breaker and then remove the panels 2 Annually remove the panels and clean the inside of the machine including the base side panels condenser etc 3 Never remove the ins...

Страница 11: ...rotate the timer counterclockwise as this would damage the internal mechanism Align the current time of day with the arrow B on the timer face This is a 24 hour timer showing both A M and P M 2 Progra...

Страница 12: ...afety Water Line Solenoid Valve is not used do not use 1 and 2 poles If the remote fill system is equipped with Sold out switches connect their wires to 3 and 4 poles for one bowl unit to 3 4 and 5 po...

Страница 13: ...aning Tank to the remote fill system line b Set the unit Power Switch to position I Manually energize the Autofill Device by keeping pushed the Autofill Switch located on the rear cover of each bowl i...

Страница 14: ...r s Manual 4 ROUTINE MAINTENANCE Daily inspect the machine for signs of product leaks past seals and gaskets If proper assembly does not stop leaks around seals or gaskets check for improper lubricati...

Страница 15: ...et OR 12 22800 24607 Faucet front part 13 33800 09100 Faucet gasket 14 22800 24608 Faucet rear part 15 10028 01300 Fitting locker 16 22040 00000 Fitting OR 17 00222 02345 Bent 1 4 fitting 18 10028 014...

Страница 16: ...erruptor de pared de tipo bipolar con apertura de contactos de 3 mm por lo menos No utilizar cordones conectores para enchufar el aparato al suministro de corriente el ctrica 7 El distribuidor no sale...

Страница 17: ...mezcladores seguir n funcionando 5 1 DESCRIPCION DE LOS MANDOS El distribuidor est provisto de un interruptor general y de un interruptor para la luz Cada uno de los contenedores est provisto de un i...

Страница 18: ...o fuera posible y los productos permanecieran en los contenedores con el distribuidor parado es conveniente una hora antes de apagar el aparato llevar los interruptores mezcladores y refrigeraci n en...

Страница 19: ...aporador el rascador exterior ver figura 7 y despu s el rascador interior Remover frequentemente la guarnici n posterior apretandola hasta que nose pierda l efecto ventosa ver figura 8 figura 7 figura...

Страница 20: ...gienizar espec fico preparar una soluci n de agua e hipoclorito de sodio lej a uso alimenticio en la proporci n de 1 cucharadita por cada 2 litros de agua 3 Colocar en la soluci n todas las partes a h...

Страница 21: ...ectuada si es necesario solamente como una ulterior prevenci n adicional a la higienizaci n del aparato desmontado descrito anteriormente pero no debe sustituir jam s a la efectuada con el aparato des...

Страница 22: ...iginales del fabricante 4 Para prevenir da os al distribuidor las partes de pl stico deben ser lubricadas solamente con la grasa suministrada por el fabricante u otra grasa compatible con policarbonat...

Страница 23: ...tador Este es un contador que muestra las 24 horas AM y PM 2 programar el contador de descongelaci n presionando las lenguetas indicadas con la letra C que corresponden a las horas prefijadas para la...

Страница 24: ...ricamente a los polos 1 y 2 de la MORSETTIERA No usar los polos 1 y 2 si no viene utilizada alguna electrovalvula de seguridad para el agua Si en el sistema de alimentaci n est n instalados los sensor...

Страница 25: ...aciada siguiendo los siguientes pasos 1 Usar un recipiente limpio para cada uno de los siguentes puntos a Recipiente para limpieza rellenar con agua potable caliente 50 60 C b Recipiente por higenizac...

Страница 26: ...se haya obtenido un sabor satisfactorio Nota la higienizaci n del sistema de recarga automatica debe ser seguido de la limpieza e higienizaci n del distribuidor como viene ilustrado en el manual de in...

Страница 27: ...28 03212 OR grifo 12 22800 24607 Lado anterior grifo 13 33800 09100 Goma del grifo 14 22800 24608 Lado posterior grifo 15 10028 01300 Metal de fijaci n 16 22040 00000 OR conexi n 17 00222 02345 Tubo c...

Страница 28: ...SPARE PARTS LIST NHT UL AF B L A C K 2442_49 V 1 2 07C29...

Страница 29: ...rear cover Tapa posterior nero 15 22800 16404 Black power switch box Panel para interruptor general 45 22800 00204 NHT 1P 2 3 UL black panel for defrost timer Panel para contador de descongelaci n ner...

Страница 30: ...ranaje 24 10028 03204 Bushing Buje 5 10028 03200 Rotor spacer Distancial del rotor 14 10028 03203 3 3 mm spacer Distancial 3 3 mm 25 10028 03205 Washer Arandela 6 33800 03802 Gear box with bushing Caj...

Страница 31: ...NHT UL AF BL Ugolini spa 31 NOTES...

Страница 32: ...CECILWARE CORPORATION 43 05 20th Avenue Long Island City N Y 11105 Tel 800 935 2211 Fax 718 932 7860 Email cecilware aol com www cecilware com 2442_49 R1 5 07D11...

Отзывы: