background image

NHT UL AF BL

Ugolini spa

13

ENGLISH

located on the rear wall.
Its functions are as follows:

To operate the Autofill Device:

1 - Set the power switch of the unit to I position.
2 - If it is first time operation: manually energize the Autofill

Device, by keeping pushed the Autofill Switch in position II,
until the priming is completed. Set the Autofill switch to I
position. 
If this is not first time operation: set Autofill switch to I
position.

3 - Set the unit mixer/refrigeration switch of the bowl to

II position.

Note:

 when Autofill switch is set to position 0, the unit performs

as a standard unit not equipped with Autofill Device.

3. 2 OPERATIONAL HELPFUL HINTS

1 - When the remote fill system is equipped with Sold-out

switches if a product sold-out occurs the Autofill Device
automatically stops and acoustic and visual alarms are
activated. Once product is restored, by keeping manually
pushed the Autofill switch (located in the rear wall) in II
position, it is possible to manually reactivate the remote fill
system as already told in 3.1.

2 - The 1.25 Amps Fuse located near the terminal block has

the purpose to protect the Autofill Devices from short
circuits or overloads on #1 and #2 poles.

3 - After cleaning and sanitizing procedures carefully dry the

bowl and the clip probe to avoid that the water present on
the bowl may be understood as level reaching the probe
and “causing of stopping of the refill”.

3. 3 IN-PLACE SANITIZATION

T h e   I n - P l a c e   S a n i t i z a t i o n   o f   t h e   A u t o f i l l   s y s t e m   i s
recommended to guarantee the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
Prior to perform the In-Place Sanitization the machine must be
emptied of product. To do this proceed as follows:

1 - Use a clean tank for each of the following:

a -Cleaning Tank - fill with warm (45-60 °C / 120 - 140 °F)

potable water.

b -Sanitizing Tank - fill with sanitizing solution (100 PPM

available chlorine concentration or 1 spoon of sodium

hypoclorite diluted with half a gallon of water) according

to your local  Health Codes and manufacturer’s

specifications.

2 - Repeat the following procedure on each of the unit bowls:

a -Disconnect the beverage source and in place of it

connect the Cleaning Tank to the remote fill system line.

b -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the

Autofill Switch (located on the rear cover of each bowl)

in position II, until the cleaning water flows free from any

beverage residue.

Set the unit Power Switch to position 0 and drain all the

liquid from the bowl.

c -Disconnect the Cleaning Tank and in place of it connect

the Sanitizing Tank to the remote fill system line.

d -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the

Autofill Switch (located on the rear cover of each bowl)

in position II, until sanitizing solution only outflows.

Flush at least a quarter of a gallon of sanitizing solution

to make sure that all the system has been filled with it.

Set the unit Power Switch to position 0 and drain from

the bowl all the sanitizing solution.

e -Disconnect the Sanitizing Tank and in place of it

connect the Beverage source to the remote fill system

line.

f -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the

Autofill Switch (located on the rear cover of each bowl)

in position II, until full strength beverage outflows.

Set the unit Power Switch to position 0 and drain all the

liquid from the bowl.

g -Set the unit Power Switch to position I. Manually

energize the Autofill Device, by keeping pushed the

Autofill Switch (located on the rear cover of each bowl)

in position II, dispense a cup of beverage and check its

taste.

h -If not satisfactory, drain all the liquid from the bowl and

repeat point G until obtaining a satisfactory tasting drink.

I position

: Autofill Device is turned ON, provided that the

power switch of the unit is set to I.

0 position

: Autofill Device is turned OFF.

II position

: Autofill Device may be manually activated

(momentary position). By keeping manually
pushed the switch in this II position, it is
possible to manually activate the refilling by-
passing all the controls (both the clip probe and
the sold-out switches). This feature is useful for
priming in the first time operation or whenever a
sold-out occurs. The same feature is also
helpful for cleaning and sanitizing procedures.

-

set the Autofill switch to 0 position.

-

set the unit power switch to I position

-

set the unit mixer/refrigeration switch to I position (Soft
Drink mode)

-

place a pail under each faucet and drain all product from
bowls

-

set all control switches to 0 position

Содержание NHT-1P-UL

Страница 1: ...O P E R A T O R S M A N U A L MANUAL DE INSTRUCCIONES NHT UL AF ENGLISH ENGLISH ESPA OL B L A C K...

Страница 2: ......

Страница 3: ...7 5 3 2 CLEANING 8 5 3 3 SANITIZING 9 5 3 4 ASSEMBLY 9 5 4 IN PLACE SANITIZATION 10 5 5 REAR SEAL MAINTENANCE 10 6 ROUTINE MAINTENANCE 10 6 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSON...

Страница 4: ...0 60 Hz areas applications Should you prefer to connect the unit directly to the mains connect the supply cord to a 2 pole wall breaker whose contact opening is at least 3 mm Do not use extension cord...

Страница 5: ...d a light switch In addition each bowl is individually operated by a mixer refrigeration switch In fact it is possible to dispense both soft drinks and Granita When a bowl is in Soft Drink mode the be...

Страница 6: ...be refilled after the product level drops lower than half of the evaporator cylinder and at the start of each day 7 For good product conservation the dispenser must run overnight at least in Soft Dri...

Страница 7: ...I position set mixer refrigeration switch es to I position Soft Drink mode place a pail under each faucet and drain all product from bowls set all control switches to the 0 position 5 3 1 DISASSEMBLY...

Страница 8: ...l soap 2 Prepare at least two gallons of a warm 45 60 C 120 140 F sanitizing solution 100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with half a gallon of water acco...

Страница 9: ...the gasket and its front fastening hooks are properly engaged see figure 15 figure 15 8 Use fresh product to chase any remaining sanitizer from the bottom of the bowl s Drain this solution Do not rin...

Страница 10: ...it or switch off the 2 pole wall breaker and then remove the panels 2 Annually remove the panels and clean the inside of the machine including the base side panels condenser etc 3 Never remove the ins...

Страница 11: ...rotate the timer counterclockwise as this would damage the internal mechanism Align the current time of day with the arrow B on the timer face This is a 24 hour timer showing both A M and P M 2 Progra...

Страница 12: ...afety Water Line Solenoid Valve is not used do not use 1 and 2 poles If the remote fill system is equipped with Sold out switches connect their wires to 3 and 4 poles for one bowl unit to 3 4 and 5 po...

Страница 13: ...aning Tank to the remote fill system line b Set the unit Power Switch to position I Manually energize the Autofill Device by keeping pushed the Autofill Switch located on the rear cover of each bowl i...

Страница 14: ...r s Manual 4 ROUTINE MAINTENANCE Daily inspect the machine for signs of product leaks past seals and gaskets If proper assembly does not stop leaks around seals or gaskets check for improper lubricati...

Страница 15: ...et OR 12 22800 24607 Faucet front part 13 33800 09100 Faucet gasket 14 22800 24608 Faucet rear part 15 10028 01300 Fitting locker 16 22040 00000 Fitting OR 17 00222 02345 Bent 1 4 fitting 18 10028 014...

Страница 16: ...erruptor de pared de tipo bipolar con apertura de contactos de 3 mm por lo menos No utilizar cordones conectores para enchufar el aparato al suministro de corriente el ctrica 7 El distribuidor no sale...

Страница 17: ...mezcladores seguir n funcionando 5 1 DESCRIPCION DE LOS MANDOS El distribuidor est provisto de un interruptor general y de un interruptor para la luz Cada uno de los contenedores est provisto de un i...

Страница 18: ...o fuera posible y los productos permanecieran en los contenedores con el distribuidor parado es conveniente una hora antes de apagar el aparato llevar los interruptores mezcladores y refrigeraci n en...

Страница 19: ...aporador el rascador exterior ver figura 7 y despu s el rascador interior Remover frequentemente la guarnici n posterior apretandola hasta que nose pierda l efecto ventosa ver figura 8 figura 7 figura...

Страница 20: ...gienizar espec fico preparar una soluci n de agua e hipoclorito de sodio lej a uso alimenticio en la proporci n de 1 cucharadita por cada 2 litros de agua 3 Colocar en la soluci n todas las partes a h...

Страница 21: ...ectuada si es necesario solamente como una ulterior prevenci n adicional a la higienizaci n del aparato desmontado descrito anteriormente pero no debe sustituir jam s a la efectuada con el aparato des...

Страница 22: ...iginales del fabricante 4 Para prevenir da os al distribuidor las partes de pl stico deben ser lubricadas solamente con la grasa suministrada por el fabricante u otra grasa compatible con policarbonat...

Страница 23: ...tador Este es un contador que muestra las 24 horas AM y PM 2 programar el contador de descongelaci n presionando las lenguetas indicadas con la letra C que corresponden a las horas prefijadas para la...

Страница 24: ...ricamente a los polos 1 y 2 de la MORSETTIERA No usar los polos 1 y 2 si no viene utilizada alguna electrovalvula de seguridad para el agua Si en el sistema de alimentaci n est n instalados los sensor...

Страница 25: ...aciada siguiendo los siguientes pasos 1 Usar un recipiente limpio para cada uno de los siguentes puntos a Recipiente para limpieza rellenar con agua potable caliente 50 60 C b Recipiente por higenizac...

Страница 26: ...se haya obtenido un sabor satisfactorio Nota la higienizaci n del sistema de recarga automatica debe ser seguido de la limpieza e higienizaci n del distribuidor como viene ilustrado en el manual de in...

Страница 27: ...28 03212 OR grifo 12 22800 24607 Lado anterior grifo 13 33800 09100 Goma del grifo 14 22800 24608 Lado posterior grifo 15 10028 01300 Metal de fijaci n 16 22040 00000 OR conexi n 17 00222 02345 Tubo c...

Страница 28: ...SPARE PARTS LIST NHT UL AF B L A C K 2442_49 V 1 2 07C29...

Страница 29: ...rear cover Tapa posterior nero 15 22800 16404 Black power switch box Panel para interruptor general 45 22800 00204 NHT 1P 2 3 UL black panel for defrost timer Panel para contador de descongelaci n ner...

Страница 30: ...ranaje 24 10028 03204 Bushing Buje 5 10028 03200 Rotor spacer Distancial del rotor 14 10028 03203 3 3 mm spacer Distancial 3 3 mm 25 10028 03205 Washer Arandela 6 33800 03802 Gear box with bushing Caj...

Страница 31: ...NHT UL AF BL Ugolini spa 31 NOTES...

Страница 32: ...CECILWARE CORPORATION 43 05 20th Avenue Long Island City N Y 11105 Tel 800 935 2211 Fax 718 932 7860 Email cecilware aol com www cecilware com 2442_49 R1 5 07D11...

Отзывы: