Ugolini spa

4 - Remove the bowl gasket from its seat (see figure 9).

figure 9

5 - Dismantle the faucet assembly (see figure 10).

figure 10

6 - Slide the drip tray out and empty it.

5. 3. 2 CLEANING

1 - Prepare at least two gallons of a mild cleaning solution of

wa r m   ( 45 - 6 0  ° C   /   12 0- 1 40   ° F )   p ot ab le   wa t er   a n d

dishwashing detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong
a solution can cause parts damage, while too mild a
solution will not provide adequate cleaning.

2 - Using a brush, suitable for the purpose, thoroughly clean

all disassembled parts in the cleaning solution.

3 - Do not immerse the lighted top covers in liquid. Wash them

apart with the cleaning solution. Carefully clean their
undersides. 

4 - In the same manner clean the evaporator cylinder(s) using

a soft bristle brush.

5 - Rinse all cleaned parts with cool clean water.

5. 3. 3 SANITIZING

Sanitizing should be performed immediately prior to starting

the machine. Do not allow the unit to sit for extended periods of

time after sanitization.

1 - Wash hands with a suitable antibacterial soap.

2 - Prepare at least two gallons of a warm (45-60 °C / 120-

140 °F) sanitizing solution (100 PPM available chlorine

concentration or 1 spoon of sodium hypoclorite diluted with

half a gallon of water) according to your local Health

Codes and manufacturer’s specifications.

3 - Place the parts in the sanitizing solution for five minutes.

4 - Do not immerse the lighted top covers in liquid. Carefully

wash their undersides with the sanitizing solution.

5 - Place the sanitized parts on a clean dry surface to air dry.

6 - Wipe clean all exterior surfaces of the unit. Do not use

abrasive cleaner.

5. 3. 4 ASSEMBLY

1 - Slide the drip tray into place.

2 - Lubricate faucet piston, inside auger and outer spiral (see

points A, B and C of figure 11) only with the grease
supplied by the manufacturer or other

 food grade

ATTENTION

Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source.

IMPORTANT

Do not attempt to wash any machine components in a
dishwasher.

IMPORTANT

In order to prevent any damages to the dispenser use
only a detergent suitable with plastic parts.

ATTENTION

When cleaning the machine, do not allow excessive
amounts of water around the electrically operated
components of the unit. Electrical shock or damage to
the machine may result.

Содержание NHT-1P-UL

Страница 1: ...O P E R A T O R S M A N U A L MANUAL DE INSTRUCCIONES NHT UL AF ENGLISH ENGLISH ESPA OL B L A C K...

Страница 2: ......

Страница 3: ...7 5 3 2 CLEANING 8 5 3 3 SANITIZING 9 5 3 4 ASSEMBLY 9 5 4 IN PLACE SANITIZATION 10 5 5 REAR SEAL MAINTENANCE 10 6 ROUTINE MAINTENANCE 10 6 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSON...

Страница 4: ...0 60 Hz areas applications Should you prefer to connect the unit directly to the mains connect the supply cord to a 2 pole wall breaker whose contact opening is at least 3 mm Do not use extension cord...

Страница 5: ...d a light switch In addition each bowl is individually operated by a mixer refrigeration switch In fact it is possible to dispense both soft drinks and Granita When a bowl is in Soft Drink mode the be...

Страница 6: ...be refilled after the product level drops lower than half of the evaporator cylinder and at the start of each day 7 For good product conservation the dispenser must run overnight at least in Soft Dri...

Страница 7: ...I position set mixer refrigeration switch es to I position Soft Drink mode place a pail under each faucet and drain all product from bowls set all control switches to the 0 position 5 3 1 DISASSEMBLY...

Страница 8: ...l soap 2 Prepare at least two gallons of a warm 45 60 C 120 140 F sanitizing solution 100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with half a gallon of water acco...

Страница 9: ...the gasket and its front fastening hooks are properly engaged see figure 15 figure 15 8 Use fresh product to chase any remaining sanitizer from the bottom of the bowl s Drain this solution Do not rin...

Страница 10: ...it or switch off the 2 pole wall breaker and then remove the panels 2 Annually remove the panels and clean the inside of the machine including the base side panels condenser etc 3 Never remove the ins...

Страница 11: ...rotate the timer counterclockwise as this would damage the internal mechanism Align the current time of day with the arrow B on the timer face This is a 24 hour timer showing both A M and P M 2 Progra...

Страница 12: ...afety Water Line Solenoid Valve is not used do not use 1 and 2 poles If the remote fill system is equipped with Sold out switches connect their wires to 3 and 4 poles for one bowl unit to 3 4 and 5 po...

Страница 13: ...aning Tank to the remote fill system line b Set the unit Power Switch to position I Manually energize the Autofill Device by keeping pushed the Autofill Switch located on the rear cover of each bowl i...

Страница 14: ...r s Manual 4 ROUTINE MAINTENANCE Daily inspect the machine for signs of product leaks past seals and gaskets If proper assembly does not stop leaks around seals or gaskets check for improper lubricati...

Страница 15: ...et OR 12 22800 24607 Faucet front part 13 33800 09100 Faucet gasket 14 22800 24608 Faucet rear part 15 10028 01300 Fitting locker 16 22040 00000 Fitting OR 17 00222 02345 Bent 1 4 fitting 18 10028 014...

Страница 16: ...erruptor de pared de tipo bipolar con apertura de contactos de 3 mm por lo menos No utilizar cordones conectores para enchufar el aparato al suministro de corriente el ctrica 7 El distribuidor no sale...

Страница 17: ...mezcladores seguir n funcionando 5 1 DESCRIPCION DE LOS MANDOS El distribuidor est provisto de un interruptor general y de un interruptor para la luz Cada uno de los contenedores est provisto de un i...

Страница 18: ...o fuera posible y los productos permanecieran en los contenedores con el distribuidor parado es conveniente una hora antes de apagar el aparato llevar los interruptores mezcladores y refrigeraci n en...

Страница 19: ...aporador el rascador exterior ver figura 7 y despu s el rascador interior Remover frequentemente la guarnici n posterior apretandola hasta que nose pierda l efecto ventosa ver figura 8 figura 7 figura...

Страница 20: ...gienizar espec fico preparar una soluci n de agua e hipoclorito de sodio lej a uso alimenticio en la proporci n de 1 cucharadita por cada 2 litros de agua 3 Colocar en la soluci n todas las partes a h...

Страница 21: ...ectuada si es necesario solamente como una ulterior prevenci n adicional a la higienizaci n del aparato desmontado descrito anteriormente pero no debe sustituir jam s a la efectuada con el aparato des...

Страница 22: ...iginales del fabricante 4 Para prevenir da os al distribuidor las partes de pl stico deben ser lubricadas solamente con la grasa suministrada por el fabricante u otra grasa compatible con policarbonat...

Страница 23: ...tador Este es un contador que muestra las 24 horas AM y PM 2 programar el contador de descongelaci n presionando las lenguetas indicadas con la letra C que corresponden a las horas prefijadas para la...

Страница 24: ...ricamente a los polos 1 y 2 de la MORSETTIERA No usar los polos 1 y 2 si no viene utilizada alguna electrovalvula de seguridad para el agua Si en el sistema de alimentaci n est n instalados los sensor...

Страница 25: ...aciada siguiendo los siguientes pasos 1 Usar un recipiente limpio para cada uno de los siguentes puntos a Recipiente para limpieza rellenar con agua potable caliente 50 60 C b Recipiente por higenizac...

Страница 26: ...se haya obtenido un sabor satisfactorio Nota la higienizaci n del sistema de recarga automatica debe ser seguido de la limpieza e higienizaci n del distribuidor como viene ilustrado en el manual de in...

Страница 27: ...28 03212 OR grifo 12 22800 24607 Lado anterior grifo 13 33800 09100 Goma del grifo 14 22800 24608 Lado posterior grifo 15 10028 01300 Metal de fijaci n 16 22040 00000 OR conexi n 17 00222 02345 Tubo c...

Страница 28: ...SPARE PARTS LIST NHT UL AF B L A C K 2442_49 V 1 2 07C29...

Страница 29: ...rear cover Tapa posterior nero 15 22800 16404 Black power switch box Panel para interruptor general 45 22800 00204 NHT 1P 2 3 UL black panel for defrost timer Panel para contador de descongelaci n ner...

Страница 30: ...ranaje 24 10028 03204 Bushing Buje 5 10028 03200 Rotor spacer Distancial del rotor 14 10028 03203 3 3 mm spacer Distancial 3 3 mm 25 10028 03205 Washer Arandela 6 33800 03802 Gear box with bushing Caj...

Страница 31: ...NHT UL AF BL Ugolini spa 31 NOTES...

Страница 32: ...CECILWARE CORPORATION 43 05 20th Avenue Long Island City N Y 11105 Tel 800 935 2211 Fax 718 932 7860 Email cecilware aol com www cecilware com 2442_49 R1 5 07D11...

Отзывы: