CE+T Power Bravo 10 - 48/230 Скачать руководство пользователя страница 1

Copyright © 2013. Construction electroniques & telecommunications S.A.  
All rights reserved. The contents in document are subject to change without notice.
The products presented are protected by several international patents and trademarks.
Address: CE+T S.a, Rue du Charbonnage 12, B 4020 Wandre, Belgium
www.cet-power.com - [email protected]

• 

DUAL INPUT INVERTER

Commercial Power as default source

• 

AC BACKUP IN A DC ENVIRONMENT

Leverage your existing DC infrastructure

• 

ONE STOP SHOP 

Wide output power range

• 

HARSHEST AC INPUT CONDITIONS

Without compromising the quality of the AC output

BEYOND THE INVERTER 

THE NEW GENERATION OF POWER CONVERTERS

BRAVO 10 - 48/230

User Manual V1.2

 

www.cet-power.com

 Belgium, China, India, Luxembourg, Malaysia, Russia, Turkey, United Kingdom, United States, Australia & Germany

Содержание Bravo 10 - 48/230

Страница 1: ...www cet power com info cet power com DUAL INPUT INVERTER Commercial Power as default source AC BACKUP IN A DC ENVIRONMENT Leverage your existing DC infrastructure ONE STOP SHOP Wide output power rang...

Страница 2: ...x mode Walk in mode 11 5 Building Blocks 12 5 1 Bravo 10 48 230 12 5 1 1 Inverter 12 5 1 2 Sub rack 14 5 2 Controller Unit 14 5 2 1 Inview S 14 5 2 2 Inview S Connections 14 5 2 3 Inview S Slot 15 5 3...

Страница 3: ...roller Inview S Slot 31 9 2 1 Removal 31 9 2 2 Inserting 31 9 3 Controller Inview S 32 9 3 1 Panel Mounting 32 9 4 Module Fan 33 10 Manual By Pass Optional 34 10 1 Pre requisites 34 10 2 Manual By Pas...

Страница 4: ...DD MM YYYY Modified page number Modifications 1 0 03 12 2018 First release of the Manual 1 1 19 08 2019 Added Inview S Slot information 1 2 25 11 2019 25 to 29 34 35 Updated inview S and MBP section 4...

Страница 5: ...p solution that unlike most used UPS s Maximizes the operator s applications uptime Operates with lowest OPEX Provides best protection to disturbances Optimizes footprint Our systems are Modular Truly...

Страница 6: ...PWR Power ESD Electro Static Discharge MET Main Earth Terminal MBP Manual By pass MBB Measure Box Battery TCP IP Transmission Control Protocol Internet Protocol USB Universal Serial Bus LAN Local Acce...

Страница 7: ...or experience related to electrical maintenance Please follow the procedures contained in this Manual and note all the DANGER WARNING AND NOTICE marks contained in this Manual Warning labels must not...

Страница 8: ...ates within 5 seconds Default setting is 60 seconds The system is designed for installation within an IP20 or IP21 environment When installed in a dusty or humid environment appropriate measures air f...

Страница 9: ...operation Contact may result in fatal injury 3 5 Replacement and Dismantling ESD Strap must be worn when handling PCB s and open units CE T cannot be held responsible for disposal of the Inverter syst...

Страница 10: ...s the nominal current for a period of 20 ms max in the event of down stream failures The upstream breakers do not have to be oversized to prevent tripping The overload capacity is 150 for 15 seconds T...

Страница 11: ...Mains input AC is the primary source whilst DC works as backup The ECI is designed to operate on Mains on a permanent basis and to deliver output voltage conditioned with low THD The output sine wave...

Страница 12: ...Bravo 10 48 230 General Part Number T611730201 Cooling Audible noise Fan forced cooling 65 dBA at one meter MTBF 240 000 hrs MIL 217IF Dielectric strength DC AC 4300 Vdc RoHS Compliant Operating T Re...

Страница 13: ...mpact recovery time 10 90 0 4 ms Nominal current 5 4 A 230 Vac Crest factor at nominal power 3 1 for load P F 0 7 Short circuit clear up capacity 0 20 ms 21 7 A for 20 ms Short circuit current after 1...

Страница 14: ...ough inbuilt powerful touch screen graphic display In addition to the touch screen display the user can also access the system information through the web interface and SNMP protocol The Inview S inte...

Страница 15: ...wer Supply converter and the part number is T602004120 5 2 3 Inview S Slot Inview S Slot is an advanced monitoring and controller unit for Bravo 10 and Sierra 10 power systems The product is specially...

Страница 16: ...t and it is from external Auxiliary power supply converter This power should not be shared with other devices By default Inview S Slot works on output DC from modules If DC is not present it takes 12...

Страница 17: ...th Inview S Slot A la Carte is available in both EPC and REG mode Dual input AC and DC inverter modules EPC 96 efficiency during normal operation EPC Always conditioned and filtered output voltage Sea...

Страница 18: ...e phase are not mixed with modules from another phase When the system is running modules can be moved from one phase to another without issue 7 1 Mounting kit for Bravo 10 shelf The fixing brackets to...

Страница 19: ...be rated at Min 90 deg C Electrical terminations shall be tightened with 5 Nm All connection screws are M5 x 12 mm DC Input Common per shelf check DC polarity AC Input AC output Common per shelf chec...

Страница 20: ...avoid damaging the connectors terminals and PCB in the shelf AC IN and OUT cables entry Right end of the shelf 1 Knock out DC and Signal cables entry Left end of the shelf 2 Knock outs Knock outs are...

Страница 21: ...l be reconnected at the same time as or before the line conductors WARNING Input Neutral is required to operate the Inverter UPS In TN S System no 4 pole input switch or circuit breaker shall be used...

Страница 22: ...only be accessed if Inview S Slot connected to that shelf 6 Pin 8 Pin ON OFF CE T COM port Remote To Inview S K1 K2 NO NO NC NC C C Power PE D1 D2 CAN Modbus RS485 Inview S Slot Terminals 7 2 9 1 Remo...

Страница 23: ...ll Green Warning If remote ON OFF is not used pin 2 and 3 MUST be bridged together 7 2 9 2 Internal bus Bus 6 pin Bus 8 pin In a la carte system Internal bus is pre installed and connected in series f...

Страница 24: ...reen orange alternatively Recovery mode after boost 10 In short circuit condition Permanent orange Starting mode Blinking orange Modules cannot start Check Inview Blinking red Recoverable fault Perman...

Страница 25: ...tons for next and previous page In some pages Up and Down navigation buttons appear at the right side indicating more contents are present 2 Information Area Provides information about the correspondi...

Страница 26: ...eration The LCD is a 1 8 inch touch screen and user can only view the system details through the interface 1 2 Navigation arrow 1 Interface area Interface area provides information about the correspon...

Страница 27: ...ure The home page is the default page in the LCD interface and other pages are arranged in the below sequence Inview S Slot LCD Interface Events Info Home Action DC AC Out System AC In Logs 8 4 Inview...

Страница 28: ...em parameter values An auto logout feature is available to avoid a user being connected all the time When no action is performed for more than 10 minutes the session will expire and goes to login scre...

Страница 29: ...ome Page 1 2 3 4 5 1 AC Input Clicking on the AC Input region displays the page contain all measurements regarding AC Input 2 DC Clicking on the DC region displays the page contain all measurements re...

Страница 30: ...multaneously pull the module using front handle 3 Remove the module from shelf and replace with a new module or dummy cover Push the pin and pull the module Remove the module from shelf Insert the pin...

Страница 31: ...ove the module from shelf Insert the pin into the hole Pin Hole 9 2 2 Inserting 1 Place the Inview S Slot and slide into the shelf 2 Push the unit firmly until the controller rear part is engaged corr...

Страница 32: ...he four latches at the rear side of the Inview S in the panel sheet 3 Connect required connection cables to the Inview S 4 Place the panel sheet in the system and fix it with screws Place the Inview S...

Страница 33: ...crew driver press firmly to release the lock of the fan connector and remove it from the board Note the fan connector position 5 Remove the front cover with fan Note the fan position Remove the screw...

Страница 34: ...nects all AC voltage on the shelves but has no effect on the DC feeding the converter and the remote alarm terminal It is requested in order to reduce the inrush current during manual by pass operatio...

Страница 35: ...he system and its auxiliary should be wired as per the following Note The below connection is for a sub rack system and auxiliary Aux number varies depending upon the MBP switch So it is recommended t...

Страница 36: ...l cables are strained relived Make sure that all breakers are according to recommendation and local regulations Make sure that DC polarity is according to marking Re tighten all electrical termination...

Страница 37: ...t to have all module operating when running on DC and have module failure when AC input recover from fault condition Installation and commissioning must be done and conducted by trained people fully a...

Страница 38: ...me parameters should be adapted according to the site condition Switch OFF AC IN and check if system is working on DC Switch ON AC IN and check if system correctly transferred load on AC Switch OFF sy...

Страница 39: ...that Inview is present and properly inserted Check remote ON OFF terminal Check the configuration and setting Check threshold level Inverter only run on AC or DC Check AC input present and in range AC...

Страница 40: ...tranet Repair registering guidelines may be requested by email at repair cet power com The RMA number should be mentioned on all shipping documents related to the repair Be aware that products shipped...

Страница 41: ...module by air suction blower or vacuum cleaner Check module system load Check Correct inverter mapping DC group AC group Address Change configuration file to validate that system operates on both sup...

Страница 42: ...all with integrated service If such SLA is in place you must call their assistance first If your vendor doesn t provide such assistance you may contact CE T through email customer support cet power co...

Страница 43: ......

Отзывы: