Edition 05/2008, Version 1.0.0, LRC-M1
Ausgabe 05/2008, Version 1.0.0, LRC-M1
Subject to Technical Changes
Technische Änderungen vorbehalten
11
a)
Figure 5,3a: Processor board with LEDs
Figure 5.3a: Rechnerkarte mit LEDs
LED
Description
1: Power On
Lights orange
Mains connected.
2: RF Scan: Also see chapter 5.3.2.
Lights orange/red Scanning for transmitter.
OFF
Transmitter found.
3: RF-reception
Lights green
Valid data is received,
K0-relays are activated.
Lights orange
Valid data is received,
K0-relays are deactivated.
lights red:
Invalid data (from a different
transmitter) received.
OFF:
No transmitter identified.
4: Movement commands
Lights green
Commands received.
5: Error indication
Blinks red
Error detected, see chapter
„Troubleshooting“.
6 Error Indication (not visible from outside, located on
processor board)
Blinks red
Error detected, see chapter
„Troubleshooting“.
Note
!
When the receiver unit is first turned on, it scans
(RF Scan) to find its assigned transmitter unit.
This process can take up to 2 minutes.
b)
Abbildung 5.3b: Receiver front cover
Abbildung 5.3b: Empfänger-Deckel
LED
Beschreibung
1: Power On
Leuchtet orange
Am Empfänger liegt Spannung an.
2: HF-Scan: Siehe auch Kapitel 5.3.2
Leuchtet orange/rot
Scan (suchen) nach Sender.
AUS
Sender gefunden.
3: HF-Empfang
Leuchtet grün
Gültige Daten werden empfangen,
K0-Relais aktiviert.
Leuchtet orange
Gültige Daten werden empfangen,
K0-Relais deaktiviert.
Leuchtet rot
Ungültige Daten (eines anderen
Senders) werden empfangen.
AUS
Kein Sender erkannt.
4: Fahrbefehle
Leuchtet grün
Befehle empfangen.
5: Fehleranzeige
Blinkt rot
Fehler festgestellt, siehe Kapitel
„Fehlerbehebung“.
6 Fehleranzeige (nicht von außen sichtbar, befindet sich
auf der Rechnerkarte)
Blinkt rot
Fehler festgestellt, siehe Kapitel
„Fehlerbehebung“.
Hinweis
!
Wird der Empfänger zum ersten Mal einge-
schaltet, sucht (HF-Scan) er nach seinem
zugehörigen Sender. Dieser Vorgang kann bis zu
2 Minuten dauern.