![Casselin Sigma 2200i Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/casselin/sigma-2200i/sigma-2200i_owners-manual_2572561040.webp)
40
3
One speaker or the subwoofer seems not to be playing.
P
If the problem occurs with all inputs, check the speaker wires for
secure connections.
P
If the problem occurs with only one input, check the
interconnect cables between the source component and the
Sigma 2200i.
P
Check the balance control setting by pressing MENU on the
front panel
,
and then verify the balance control setting is not
turning one channel off or reducing it’s output.
P
If the problem occurs for the subwoofer, make sure it is active on
the configuration assigned to this source button.
4
The IR remote control does not seem to function.
P
Ensure that there are no obstacles between the IR remote and the
IR sensor, located to the right of the
Mute
button.
P
Check the orientation and if necessary, replace the batteries in
the remote control.
5
There is a hum coming out of the speakers.
P
If you are using single-ended interconnects, make sure they are
not placed alongside any AC power cords. Also make sure that
they are not too long – long single-ended interconnecting cables
have a natural tendency to pick up noise even when shielded.
P
If any source components are connected to cable TV, try
disconnecting the cable television line from the source
component. If the hum goes away, you need an isolation device
between your cable TV converter and the source component.
Your Classé dealer can help you obtain one of these inexpensive
devices.
6
The unit sometimes turns itself off unexpectedly.
P
A power-saving feature called Auto-Standby will put the unit
into standby after 15-20 minutes whenever there is no input
signal, the volume is set to a very low level or the unit remains in
mute mode. To disable this feature, contact your Classe dealer.
network/streaming
troubleshooting
1
The Network Status page shows Not Connected and there are
no green and amber lights illuminated on the Ethernet cable
connector on the rear panel.
P
Check that the Ethernet cable is connected to an active Network.
P
Try substituting the Ethernet cable to confirm whether the cable
itself is functioning.
P
If using a wireless bridge, make sure it is connected to your
wireless Network and that you are using the correct connector
(labeled <...> on the Airport Express).
2
The Network status indicates Connected but the Sigma 2200i
does not appear on your list of devices in AirPlay or on your
DLNA Media Player.
P
Restart all participating components one at a time until the
problem is resolved. First the media player, then the Sigma 2200i
(cycle the power off and on) and then your router. If the problem
persists verify that you have a valid IP address. If your address is
“Limited Auto IP” then the Sigma 2200i has auto assigned itself
an address and this indicates that your DHCP IP address server
is not working.
Содержание Sigma 2200i
Страница 1: ...Owner s Manual Sigma 2200i Stereo Integrated Amplifier...
Страница 47: ...47...