4.1.8.4 Creep Setting (Menu Code 8186)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 6. Creep Setting)
- Choose ‘N’ or ‘Y’ to determine the Creep Compensation
- At Span Fine Adjust, enter the Changed internal value after increasing max weight for 30minute.
- Creep Direction 1: (+) , 0: (-)
4.1.8.5 A/D Firmware (Menu Code 8187)
(Calibration MENU -> 1. Calibration -> 8. Factory Setting -> 7. A/D Firmware)
- It shows Firmware version of A/D module.