4.1.7 Zero & Tare Setting (Menu Code 8170)
(Calibration MENU -> 1. Calibration -> 7. Zero & Tare Setting)
CAUTION: This Setting is part of (OIML, NTEP, etc) regulation must be setting by the local restriction.
① Init-Zero range (%)
Before Sales mode you need to compare Calibrated A/D value and current A/D value need to be in the safe
range order to function property. Scale will not function if there is a weight or any distortion on the tray.
② Re-zero Range (%)
During the usage, zero range might be unstable cause by tray and other condition. You can set the
allowance percent (%) range for zero display. (OIML regulation restricts 4% of maximum weight range can
be used)
③ Overload Range(d)
You can set the maximum overload range. For example, [9] set as 15.045g (5gx[9]=45g). If the weight is
over 15.045 overload message will appear.
④ Accumulation(Y/N)
You can set Tare weights additively. This is useful additional package is used for different goods.
⑤ Subtraction(Y/N)
You can set Tare only if the other tare weight is less then the first value.
⑥ Gross Zero Mark(Y/N)
You can see zero state when total weight on the tray is 0.
NOTE: * Gross weight is display will display total weight. (Tare setting does not effect)
* Net weight is remain value of Tare weight.
* If Tare setting is set as “N” the gross weight and net weight value is same.