`
52
<Limit mode 1> Relay Operation Graph when #1 of F51 is set
Weight
Step4
Step3
Step2
Step1
Near Zero
Tare External Input
SP1 Output 1
SP2 Output 2
SP3
Output 3
SP4 Output 4
Finish Output 5
Near Zero Output 6
Note.
1. Required set value input: Step4> Step3> Step2> Step1
2. Near zero output is according to the specified range in F57.
3. T1: Refer to F52 (Delay time of weighing Finish relay output)
T2: Refer to F53 (Operation time of weighing Finish relay output)
4. Relay Output
SP1 : ON when the set value of Step1 is reached
SP2 : ON when the set value of Step2 is reached
SP3: ON when the set value of Step3 is reached
SP4: ON when the set value of Step4 is reached
Finish : ON after T1(set time), ON for the during of T2 (set time)
Near Zero: F57 set value
≥
0 range output
5. Step1`-4(SP 1-4)‘s status lamp in the front panel is operated in the same manner as the RELAY
output.
T1 T2
Содержание CI-502A
Страница 1: ... 2 ...
Страница 9: ... 10 External Appearance and Dimensions External Appearance CI 502A CI 505A ...
Страница 10: ... 11 Dimensions of the Product CI 502A CI 505A ...
Страница 11: ... 12 Front Panel Descriptions CI 502A CI 505A ...
Страница 27: ... 28 9 th Step Item MovebacktotheWeighingMode ...
Страница 67: ... 68 Weight Data 8 byte a 13 5kg 1 3 5 b 135kg 1 3 5 c 135kg 1 3 5 ...
Страница 74: ... 75 Sealing Method Sealing 1 Sealing the Indicator Sealing the Load Cell Connector ...
Страница 83: ... 84 MEMO ...
Страница 84: ... 85 MEMO ...
Страница 85: ... 86 MEMO ...
Страница 86: ... 87 MEMO ...
Страница 87: ... 88 ...
Страница 88: ... 89 ...