![CAS CI-502A Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/cas/ci-502a/ci-502a_owners-manual_2565929041.webp)
`
42
F12
Function
Set the Tare Range
Display Signification Display Signification
F11. 0
Tare key is available within
2% of the maximum weight
F11. 5
Tare key is available within
50% of the maximum weight
F11. 1
Tare key is available within
5% of the maximum weight
F11. 6
Tare key is available within
60% of the maximum weight
F11. 2
Tare key is available within
10% of the maximum
weight
F11. 7
Tare key is available within
70% of the maximum weight
F11. 3
Tare key is available within
20% of the maximum
weight
F11. 8
Tare key is available within
80% of the maximum weight
Set-up
Range
(0~9)
F11. 4
Tare key is available within
40% of the maximum
weight
F11. 9
Tare key is available within
100% of the maximum weight
F13
Function
Set the Initial Zero Range (Init Zero)
Display Signification
Display
Signification
F11. 0
Set the value within 2%
of the maximum weight
as the initial zero
F11. 5
Set the value within 50% of
the maximum weight as the
initial zero
F11. 1
Set the value within 5%
of the maximum weight
as the initial zero
F11. 6
Set the value within 60% of
the maximum weight as the
initial zero
F11. 2
Set the value within 10%
of the maximum weight
as the initial zero
F11. 7
Set the value within 70% of
the maximum weight as the
initial zero
F11. 3
Set the value within 20%
of the maximum weight
as the initial zero
F11. 8
Set the value within 80% of
the maximum weight as the
initial zero
Set-up Range
(0~9)
F11. 4
Set the value within 40%
of the maximum weight
as the initial zero
F11. 9
Set the value within 100% of
the maximum weight as the
initial zero
F14
Function
Set the Excessive Weight Check Range (Weighing Unit)
Display Signification
F14. 9
Excessive weight starts from +9 division units above
the maximum weight value.
Set-up Range
(0~99)
F14. 99
Excessive weight starts from +99 division units above
the maximum weight value.
Содержание CI-502A
Страница 1: ... 2 ...
Страница 9: ... 10 External Appearance and Dimensions External Appearance CI 502A CI 505A ...
Страница 10: ... 11 Dimensions of the Product CI 502A CI 505A ...
Страница 11: ... 12 Front Panel Descriptions CI 502A CI 505A ...
Страница 27: ... 28 9 th Step Item MovebacktotheWeighingMode ...
Страница 67: ... 68 Weight Data 8 byte a 13 5kg 1 3 5 b 135kg 1 3 5 c 135kg 1 3 5 ...
Страница 74: ... 75 Sealing Method Sealing 1 Sealing the Indicator Sealing the Load Cell Connector ...
Страница 83: ... 84 MEMO ...
Страница 84: ... 85 MEMO ...
Страница 85: ... 86 MEMO ...
Страница 86: ... 87 MEMO ...
Страница 87: ... 88 ...
Страница 88: ... 89 ...