36
F11
(0)
Set the Zero Range
±2% ~ ±100%
F12
(9)
Set the Tare Range
±2% ~ ±100%
F13
(2)
Set the Initial Zero Range (Init Zero)
±2% ~ ±100%
F14 (09)
Set the Excessive Weight Check Range
(Weight Unit)
Excessive weight is from maximum
weight value to +99 division unit above
the maximum weight value.
F15 (0)
Set-up for allowing key input in the front of
the indicator
All keys functional / only the specified
keys functional
F16
(5)
Set the purpose for Function key 1 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F17
(6)
Set the purpose for Function key 2 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F18
(1)
Set the purpose for key 4 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F19
(1)
Set the purpose for key 5 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
Communication & Print Function
F20
(01)
Set the Device ID (00~99)
Device ID
F21
(0)
Set the parity bit (0 ~ 2)
Data bit, stop bit, parity bit
F22
(0)
Set the communication data (0 ~ 2)
Transmissions of indicated value / gross
weight / net weight
F23
(4)
Set the RS-232C Baud Rate (0 ~ 8)
600bps ~ 115,200 bps
F24 (0)
Set the RS-232C-output format
(0 ~ 2)
22 bytes / 10 bytes / 18 bytes
F25
(0)
Set the RS-232C output mode (0 ~ 7)
Set 8 types of output modes
F26
(4)
Set the PRINT Baud Rate
600bps ~ 115,200 bps
F27
(3)
Set the PRT- output mode
Set 4 types of output modes
F31 (3)
Set the output data and/or print format
Set 3 types of output data and/or 6 types
of print format
F32 (0)
Automatic Print Set-up (0 ~ 2)
Manual print / Automatic print / Print in
series
F33 (0)
Initialization of Number Measured
Daily (0 ~ 1)
Maintain current number / Initialize data
after print-out
F34 (1)
User Output Message (0 ~ 1)
Do not use / Use
F35 (1)
Set the Line Feed for Print
From no line feed to adjustment in lines
after printing out 1~9 lines
F36 (00)
Set the Print Delay Time (00 ~ 99)
00: No delay in printing
99: Print after a 9.9 sec delay
F37 (0)
In Sub-total Print, Print Maximum,
Minimum and Average Values (0~1)
Print weight value / Print maximum,
minimum, and average values
F38
(0)
Select the Print Characters
CP-7100/7200, DEP-50
DLP-50
F39
(0)
Set the Print Output Range
0: All Weights (+),(-) possible for print-out
1: Weight must be (+) for print-out
Содержание CI-502A
Страница 1: ... 2 ...
Страница 9: ... 10 External Appearance and Dimensions External Appearance CI 502A CI 505A ...
Страница 10: ... 11 Dimensions of the Product CI 502A CI 505A ...
Страница 11: ... 12 Front Panel Descriptions CI 502A CI 505A ...
Страница 27: ... 28 9 th Step Item MovebacktotheWeighingMode ...
Страница 67: ... 68 Weight Data 8 byte a 13 5kg 1 3 5 b 135kg 1 3 5 c 135kg 1 3 5 ...
Страница 74: ... 75 Sealing Method Sealing 1 Sealing the Indicator Sealing the Load Cell Connector ...
Страница 83: ... 84 MEMO ...
Страница 84: ... 85 MEMO ...
Страница 85: ... 86 MEMO ...
Страница 86: ... 87 MEMO ...
Страница 87: ... 88 ...
Страница 88: ... 89 ...