Reference Manual V1.10
Software Versions 3.xx
X300-621-110
Page 47
peak value (eg. -30 is larger than 25). The
Hold
annunciator is active when the display is
showing the held weight. Refer to 5.1 Display page 19.
To perform the
Hold
function, do the following:
Press the manual
<HOLD>
key once to hold the current displayed weight.
Press the manual
<HOLD>
key again to return the display to normal weighing.
To perform the
Peak Hold
function do the following:
Press the
<PEAK>
hold key once to show the absolute peak weight reading.
Press the
<PEAK>
hold key again to return the display to normal weighing.
A long press of the
<PEAK>
hold key clears the peak value back to
0
(zero).
All printouts that print the displayed weight will use the held weight reading if it is currently
being displayed.
13.2.6. SHOW.T
The
SHOW.T
item stands for
Show Total
. The function key will be labelled
<TOTAL>
.
The
key is used not only to print the current weight but also to add that weight to the
current total.
When the
<TOTAL>
key is pressed the indicator displays
count
followed by the number of
items in the total.
After this,
TOTAL
is displayed followed by the current total weight.
If the total weight is too large to display in six digits, the weight is shown in two sections
labelled with the upper six digits displayed before the lower six digits.
A long press of the
<PRINT>
key causes the total accumulated weight to be printed and then
cleared. The SERIAL:TYPE option must be set to PRINT to activate this function.
13.2.7. HI.RES
The
<HI.RES>
key is used to switch the display between normal and a high resolution (x10)
display of the weight. The high resolution display is identified by flashing units.
13.2.8. A.TARE
The
<A.TARE>
key is used to enable the automatic tare feature. This feature when enabled
will cause the indicator to be tared whenever the weight is motionless above the autotare
threshold and has been below the autotare threshold since the last autotare. The tare weight
is reset to zero when the autotare feature is active and the gross weight is motionless within
the zero “dead” band.
Press the
<A.TARE>
key to switch between normal weighing and automatic tare mode.
An
► annunciator will appear in the middle of the right hand side of the display to
indicate that the automatic tare mode is active.