57
• Remove the fuse, and connect the ammeter with two ends of the fuse.
• Connect the tachometer to the engine (it’s not needed when there is rpm
indicator on the vehicle).
• Start the engine, and accelerate slowly, measure the charging voltage and current.
Charging voltage (V)
13.5 ~ 15.5
Charging current (A)
0.5
*Measuring condition: 5000 r/min
If the voltage is not in the range of the above-specified value, please inspect the voltage regulator.
BATTERY
The battery is an important component of the electric system. The battery used on the vehicle is
a maintenance-free battery. For long periods of storage, the battery will discharge. It should be
charged every 3 months. After 2 ~3 years of regular usage, the capacity of the battery will lessen
and will need charging. Replace with the same type of battery.
BATTERY REMOVAL
Shut down the main switch to make sure no electric current goes through the vehicle.
• Disconnect the negative battery lead wire first.
• Disconnect the positive battery.
The disconnecting order cannot be reversed. When disconnecting the
positive cable, do not touch the body of the vehicle with the removal
tool, or it will short circuit and ignite gas that will damage the battery.
BATTERY INSTALLATION
Connect the positive cable first, then connect the negative cable.
BATTERY OPEN-CIRCUIT VOLTAGE INSPECTION
Disconnect the cable on the battery terminals.
Disconnect the negative pole first, then the positive pole.
Measure the voltage between the two poles of the battery.
Full charging
13.1V
Under charging
12.3V