65
IGNITION COIL
IGNITION COIL REMOVAL
• Remove the spark plug cap.
• Remove the primary ignition coil wire.
• Remove the ignition coil-positioning bolt, and remove the ignition coil.
IGNITION COIL INSTALLATION
• Reverse the removal procedure for installation.
When installing, connect the black/yellow wire of the primary ignition coil with the
black/yellow connector of CDI, and the green wire the green connector of the CDI.
PRIMARY IGNITION COIL INSPECTION
Standard Value
0.1 ~ 1.0KΩ (20°C)
If the resistance value is ∞, it indicates the coil is bad and should be replaced.
SECONDARY IGNITION COIL INSPECTION
Install the spark plug cap, and measure the resistance value of the secondary ignition coil.
Standard Value
7 ~ 9KΩ (20°C)
If the resistance value is in the standard range, it is good; however, ∞ indicates the coil is bad.
Remove the spark plug cap, and measure the resistance value of the secondary ignition coil.
Standard Value
2 ~ 4KΩ (20°C)
The resistance value is in the standard range indicates it is good; however, ∞ indicates the coil is
bad.
The ignition coil also can be inspected and measured with the ignition testing instrument.
Please operate properly according to the instructions.
Set the measuring switch of the ignition coil on the 1.2V position, and connect the ignition coil.
Turn the switch of the testing instrument to the “ON” position, observe the spark over window and
inspect the spark over situation of the ignition coil. If it is a normal consistent spark, it is good; if
the spark does not flash consistently, it is not good.
SPARK PLUG
• Clean the carbon around the spark plug to prevent it from dropping into the cylinder Remove the
spark plug.