30
VACUUM CHAMBER INSTALLATION
• Mount the plunger and the vacuum membrane into the
carburetor body.
• Push the plunger upwards in the direction of the vacu-
um chamber cover to open the carburetor jet tube. Put
the spring in.
• Align the bulge part of the vacuum membrane with
the fillister of the carburetor body, and then mount the
vacuum chamber cover.
• Tighten the bolt.
AUTOMATIC SIDE STARTER (CHOKE)
AUTOMATIC SIDE STARTER INSPECTION
• Remove the fuel hose from the carburetor.
• Turn out the carburetor float chamber drain screw, and drain the fuel in the carburetor.
• Remove the automatic side starter lead wire, and remove the clip.
• Remove the carburetor clamp, and remove the carburetor.
• Check the condition of the connection between the two lead wires.
The choke value should be below 10V. If it exceeds the specific valve, it should be replaced.
When the engine is cold, link a hose on the reserve supply fuel line and blow very gently. If it is ob-
structed or the auto side starter is not good, it should be replaced.
• Remove the auto side starter cover.
• Remove its positioning bolts and pieces.
• Remove the auto side starter.
• Inspect the auto side starting valve and fuel injection needle for wear.
• Inspect the O-ring wear.
FLOAT CHAMBER
FLOAT CHAMBER REMOVAL
• Remove the carburetor.
• Remove the clamp, and remove the float chamber.
• Remove the O-ring, and turn out the float chamber screw, remove the float pin, and remove the
float and float valve.
• Remove the choke adjusting screw and air adjusting screw.