![Carrier NDK33BN0KB Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/carrier/ndk33bn0kb/ndk33bn0kb_operation-and-service-manual_2563853095.webp)
62-61753-21
5-1
SECTION 5 -
TECHNICIAN INTERFACE
TECHNICIAN INTERFACE
CONNECTOR ASSEMBLY
P/N 22-60661-00
Figure 5-1. Technicians Interface Connections
5.1
TECHNICIAN CONFIGURATION/ TEST
MODES (REMOVE JUMPER MODE)
The Technicians Configuration/Test Mode allows the
technician to change Configurations, test the unit
components and/or service the refrigeration system.
To place the microprocessor in the Technicians Con-
figuration/Test Mode using the technician interface
connector assembly (see Figure 5-1):
1. Place the SROS in the OFF position.
2. Locate the technician interface connector, remove
the protective plug to gain access to the wire termi-
nals.
3. Plug in connector assembly.
4. Place the SROS in the START/RUN position. The
ALARM LED will come on, the setpoint will appear,
but the refrigerated compartment Temperature will
not, and "REMOVE JUMPER" will appear in
the MessageCenter for 10 seconds. Remove the
technician interface connector assembly at this time.
TO SCROLL, THEN = TO SELECT" will appear
in the MessageCenter for 10 seconds, or until either
the UP or DOWN ARROW keys are pressed.
5. Press the UP ARROW Key to scroll through the
Menu beginning at the top.
Press the DOWN ARROW Key to scroll through the
Menu beginning at the bottom.
6. Select the Mode you wish to access,
Configuration Mode
Component Test Mode
Service Mode
and press the = key. Information on these test
modes is provided in the following sub-paragraphs:
5.1.1 Configuration Mode
a. Enter the Technicians Configuration/Test mode
(refer to Section 5.1) and select CONFIGURA-
TIONS. When "
TO SCROLL, THEN = TO
SELECT" appears in the MessageCenter:
b. Press the UP ARROW Key to scroll through the
Configuration list beginning at the top.
Press the DOWN ARROW Key to scroll through the
Configuration list beginning at the bottom.
c. To read through the Configuration list, continue to
press either the UP or DOWN ARROW keys. The
list is circular meaning that once the end is reached,
it is repeated from the beginning. Refer to Table 5-2
for information on the settings and resultant micro-
processor actions.
d. To change one of the Configurations, bring the Con-
figuration to change into the MessageCenter, and
press "=".
TO SCROLL, THEN = TO SAVE" will
show in the MessageCenter for 10 seconds Then
the selected Configuration will flash, showing the
current value. Press the UP or DOWN ARROW Key
to scroll through the list of available selections for
this Configuration.
e. Once a new value is showing in the Message-
Center, press the = Key to save the selection. The
MessageCenter will stop flashing. The new value is
now in memory.
f. Press the UP ARROW Key to continue to scroll
through the Configuration list.
5.1.2 Component Test Mode
WARNING
If the unit is in Standby Operation and
powered, voltage will be applied to high
voltage components (i.e. the fan motor
contactor) and those components will op-
erate (i.e. the fan blades will turn) when
those components are energized using
component test mode.
Component Test Mode allows the Technician to ener-
gize individual circuits for 5 minutes at a time. The
engine is not allowed to start when the Micro is in
Component Test Mode. To enter the Component Test
Mode:
a. Enter the Technicians Configuration/Test Mode
(refer to Section 5.1) and select COMPONENT
TEST MODE. When "
TO SCROLL, THEN = TO
SELECT" appears in the MessageCenter:
b. Press the UP ARROW Key to scroll through the
component
list
beginning
at
the
top.
Press the DOWN ARROW Key to scroll through the
component list beginning at the bottom.
c. Press = to select the component you wish to test.
For example, if Buzzer is selected, the buzzer will
come on, and "BUZZER OFF IN 5 MINUTES" will
appear in the MessageCenter. The minutes will
count down to 0 at which time the buzzer circuit will
be de-energized, and the MessageCenter will dis-
play the last component tested.
Should you need more than 5 minutes, the timer
may be reset to 5 minutes anytime during the test by
Содержание NDK33BN0KB
Страница 2: ......
Страница 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Страница 4: ......
Страница 14: ......
Страница 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Страница 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Страница 30: ...62 61753 21 2 6...
Страница 48: ......
Страница 212: ......
Страница 226: ......
Страница 248: ......
Страница 252: ......
Страница 262: ......
Страница 270: ......