62-61753-21
6-3
MessageCenter MESSAGES
Message
Description
EVAC / CHARGE MODE
The unit is in Service Mode, and the refrigeration system is ready to
be evacuated then charged with refrigerant. Refer to Section 5.1.3.
EXITING PRETRIP MODE
Pretrip has been aborted either by user or by a pretrip alarm.
EXITING SERVICE MODE
Service Mode has been turned off and unit is returning to normal
operation.
FUNCTION NOT CHANGED
The = key was not pressed in the allotted amount of time to select the
new Functional Parameter setting. The new setting was not stored
and the old setting will be used.
HOUR METERS NOT CHANGED
Indicates that no changes have been made to the hourmeters in ei-
ther the Configuration or functional parameter lists.
INACTIVE ALARMS IN MEMORY
There are inactive alarms in the microprocessor alarm list which have
not yet been cleared.
INSTALLED, REMOVE CARD XX
An Option PC Card has been inserted into the PC Card slot, and the
option has been installed in the microprocessor. The PC Card may
safely be removed from the slot. XX indicates the number of option
installations remaining on card.
INSTALLING OPTION, PLEASE WAIT
An Option PC Card has been inserted into the PC Card slot, and the
option is being installed in the microprocessor. DO NOT REMOVE
THE CARD WHILE THIS MESSAGE IS BEING DISPLAYED.
INSTALL STOPPED, REINSERT CARD
An Option PC Card has been inserted into the PC Card slot, and the
install process has been stopped by the PC Card not being fully in-
serted in the slot, or by being removed. Remove and reinsert PC
Card to continue.
INTELLI-SLEEP MODE
The IntelliSleep IntelliSet is active. This message alternates with
"CHANGE INTELLISET TO EXIT" at 5 second interval whether unit is
running or not
KEYPAD LOCKED-BATTERY TOO LOW Once the battery voltage goes below 7.0 Volts for 10 seconds, all of
the keys on the keypad will be locked.
LIST END, = TO CLEAR ALARMS
The end of the Alarm list has been reached. Pressing the = key will
clear the Alarm list.
LOADING INFO
A Configuration PC Card has been inserted into the PC Card slot,
and information from the Configuration card is being loaded into the
microprocessor. DO NOT REMOVE THE CARD WHILE THIS MES-
SAGE IS BEING DISPLAYED.
MAIN MENU
Consists of Configuration Mode, Component Test and Service
Modes.
MAX SETPOINT HAS BEEN REACHED
Maximum set point allowed by Configuration settings has been
reached.
MICRO WILL RESET & RESTART NOW
The microprocessor Program software has just been changed, or a
new Configuration has been programmed into the microprocessor.
The microprocessor will turn itself off then on again (similar to a com-
puter reboot) in order for the changes to be effective.
MICRO WILL STOP IN XXX SECONDS
The START / RUN-OFF switch has been turned OFF and the system
valves are closing. The display will turn off when the count down
reaches zero.
MIN SETPOINT HAS BEEN REACHED
Minimum Set Point allowed by Configuration settings has been
reached.
MODIFIED
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and one or more of
its settings have been modified.
NEW SW: = TO LOAD, TO
CANCEL
A Program PC Card has been inserted into the PC Card slot, and the
program on the PC Card is a newer version than what is already
loaded in the microprocessor. Press the = key to load the program.
Содержание NDK33BN0KB
Страница 2: ......
Страница 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Страница 4: ......
Страница 14: ......
Страница 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Страница 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Страница 30: ...62 61753 21 2 6...
Страница 48: ......
Страница 212: ......
Страница 226: ......
Страница 248: ......
Страница 252: ......
Страница 262: ......
Страница 270: ......