![Carrier NDK33BN0KB Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/carrier/ndk33bn0kb/ndk33bn0kb_operation-and-service-manual_2563853101.webp)
62-61753-21
5-7
f. When MONTH appears, press the = Key, then the
Up Arrow Key. The MessageCenter will begin to
flash, indicating that it is ready to accept changes.
Use the Up or Down Arrow Keys to scroll through
the number list until the correct number of the cur-
rent month appears. Press the = Key to enter that
number for the month.
g. Now, press the Up Arrow Key to go to Day.
h. Using the same key presses as in f. and g. above,
continue to enter the correct numerical value for the
Day, Year, Hour and Minute.
i. When you are finished, the MessageCenter will
show PRESS = TO SAVE TIME CHANGES.
NOTE
If you do not press the = Key, the time chang-
es will not be saved.
j. Press the Up Arrow key again, and SET NEW
HOURS appears. Press the = key then the Up Ar-
row key to enter that menu.
k. The first hour meter is Engine Protect Hours. Press
the = key to select this meter. The cursor will be
blinking on the ten-thousands place. Press the Up or
Down Arrow key to select the correct value, then
press the = key. If the correct number in any of the
locations is 0 (zero), just press the = key to enter 0
as the value and move the cursor to the next place.
For example, if you are entering 567 hours, you will
press the = key twice to leave a 0 for the first two
numbers, then use the Up and Down Arrow keys to
scroll through the numbers to enter the correct
hours. When the correct hours for Engine Protect
Hours has been entered, press the = key to ad-
vance to the next hour meter. If an invalid number is
entered, a warning message will flash in the Mes-
sageCenter. For example, you can not enter a high-
er number of hours for Engine Protect than the
number of Switch On Hours.
NOTE
None of the "Total" hour meters are listed.
When the hours for all the hour meters are en-
tered, the micro will add the correct hours to-
gether and calculate the Total Engine Hours,
and Total Switch On Hours. When the end of
the list is reached PRESS = TO SAVE
HOURS will be displayed. Pressing the = key
will save the hours, and return you to the Con-
figuration list.
If you do not press the = key, none of the time
hours or cycles you just entered will be saved.
Hour meters may be changed for 60 minutes
following the initial hour entry. If an error has
been made, be certain to correct it within the
60 minute time period. Following that time, the
hour meters will count the appropriate hours
because the unit switch is on and the unit is
operating, and no further manual changes will
be allowed.
l. Now, press the Down Arrow key until SET TIME
appears. Press the = key then the Up Arrow key to
enter that menu.
NOTE
The basic Configurations and Functional Pa-
rameters may be set using the keypad. If Intel-
liSets or changes to the Data Recorder are to
be programmed, those changes require the
use of ReeferManager and PC Cards. Refer to
manual
62-10889
User’s
Guide
For
ReeferManager and Reports for complete in-
structions.
If the Configurations and Functional Parame-
ters will be set from the keypad, continue with
following Sections 5.4.3 and 5.4.4. Following
programming using the keypad or ReeferMan-
ager and Reports, continue with Section 5.4.5
- Microprocessor Final Checkout.
5.4.3 Configurations Via Keypad
a. Refer to Table 5-2 for information on the Configura-
tion settings and resultant microprocessor actions.
NOTE
Units equipped with IntelliSet MUST have the
settings installed using ReeferManager.
IntelliSet settings CANNOT be installed using
the Keypad.
b. Press an Arrow Key to go to the next Configuration.
Compare the setting already in the micro with the
setting required.
c. When a setting needs to be changed, first press the
= Key. This allows the setting to be changed.
d. Press the Up or Down Arrow Keys to scroll through
the selections for that Configuration.
e. When the desired setting is visible in the
MessageCenter, press the = Key.
f. Repeat steps b. thru e. until all Configurations have
been reviewed and changed as required.
5.4.4 Functional Parameters Via Keypad
a. Refer to Table 3-2 for information on the Micropro-
cessor Functional Parameters settings and resultant
microprocessor actions.
b. Press the Select Key, until PRESS
TO VIEW
SETTINGS appears in the MessageCenter
c. Pressing the Up Arrow Key will bring
TO
SCROLL, THEN = TO SELECT into the
MessageCenter.
d. Press the Up Arrow Key to go to the first Functional
Parameter. The MessageCenter will display DE-
FROST TIMER SET FOR X HRS.
e. To keep this setting and go to the next setting, press
the Up Arrow Key.
Содержание NDK33BN0KB
Страница 2: ......
Страница 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Страница 4: ......
Страница 14: ......
Страница 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Страница 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Страница 30: ...62 61753 21 2 6...
Страница 48: ......
Страница 212: ......
Страница 226: ......
Страница 248: ......
Страница 252: ......
Страница 262: ......
Страница 270: ......