Document revision history
Carrier® ChillerVu™
(OPN-PSM-MPCXPE)
Carrier Proprietary and Confidential
CARRIER CORPORATION ©2017
Installation and Start-up Guide
70
All rights reserved
Important changes to this document are listed below. Minor changes such as typographical or formatting errors are not
listed.
Date
Topic
Change description
Code*
8/7/17
Adding the Carrier® ChillerVu™ into the
i-Vu or Field Assistant system
To scan in and download CCN devices
Increased the visibility of statement about not being able to use
Field Assistant for a CCN system.
C-AE-BL-E
4/27/17
Ethernet, BACnet MS/TP, ARC156, and
CCN wiring specifications
Added CCN specs
C-TS-JN-E-RD
4/7/17
To scan in and download CCN devices Defaults to a Gateway now instead of Bridge.
C-TS-JN-E
To identify a driver in a Carrier®
ChillerVu™ in the i-Vu Pro v6.5
application
New topic.
C-TS-JN-E
To wire a BAcnet over IP network
Corrected for new driver. Use rotary switches to set the BACnet
Device Instance address.
C-TS-JN-E
Inputs
Added 5 kOhm thermistor
CA-TS-JN-E
BACnet firewall
new topic
X-D-RD-E-BL
Zone sensors
Equipment Touch
Deleted topics.
C-AE-BL-O-WB
Wiring devices to the Carrier®
ChillerVu™'s Rnet port
Removed device details and clarified lack of support except in a
custom control program.
C-AE-BL-O-WB
Input wiring specifications
Added Wireless Adapter for Wireless sensors
C-D
To wire the controller to the BACnet
MS/TP or ARC156 network
Added ARC156
C-D
Wiring for communications
Added ARC156
C-D
Carrier® ChillerVu™ specifications
Added driver, ARC156, Wireless sensors, and Wireless Adapter
C-D
Cover
What are the MPC Open XP and MPC
Open XP expanders?
Changed Carrier® ChillerVu™ to new silkscreen
C-D
To choose an IP address scheme
New topic
C-TS-JN-E
To scan in and download CCN devices Changed name - formerly, To find and download CCN devices.
C-TS-JN-E
To wire to a CCN network
Deleted Network Service Tool instructions. - Use the i-Vu®
interface instead.
C-TS-JN-E
To wire to a BACnet MS/TP network
Setting MAC address using rotary address switches removed.
C-TS-JN-E
Wiring for communications
Added clarification on baud rate for connecting to a LonWorks
SLTA or Option Card.
C-TS-JN-E
To assign a custom IP address
Corrected DIP switch setting to Enhanced Access and Assigned to
On. Added wiring specifications.
C-TS-JN-E
To obtain an IP address using DHCP
Corrected DIP switch setting to IP Addr > DHCP to Off. Added
wiring specifications.
C-TS-JN-E
To use a default IP address
Corrected DIP switch name to IP Addr. Added rotary address info
and wiring specifications.
C-TS-JN-E
To set the controller's MAC address
removed - N/A
C-TS-JN-E
Addressing the Carrier® ChillerVu™
Changed MAC address information to Device Instance
Changed Ethernet to IP
C-TS-JN-E
5/6/16
Where appropriate.
Removed references to SiteBuilder except when using multi-CCN. C-D-E-RR
Document revision history