4–33
T-316
Table 4–9 DataCORDER Pre-Trip Result Records
TEST #
TITLE
DATA
1-0
Heater On
Pass/Fail/Skip Result, Change in current for Phase A, B, and C
1-1
Heater Off
Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
2-0
Condenser Fan On
Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/Closed,
Change in currents for Phase A, B, and C
2-1
Condenser Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
3-0
Low Speed Evaporator Fan On Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
3-1
Low Speed Evaporator Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
4-0
High Speed Evaporator Fan On Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
4-1
High Speed Evaporator Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
5-0
Supply/Return Probe Test
Pass/Fail/Skip Result, STS, RTS, SRS, and RRS
5-1
Secondary Supply Probe Test
Pass/Fail/Skip Result
5-2
Secondary Return Probe Test
Pass/Fail/Skip Result
6-0
Compressor On
Pass/Fail/Skip Result, Change in currents for Phase A, B, and C
6-1
Not Applicable
Not Used
6-2
Suction Modulation Valve Open
and Closed
Pass/Fail/Skip Result, Is current or pressure limit in effect (Y,N)
6-4
Not Applicable
Not Used
6-5
Not Applicable
Not Used
7-0
High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
7-1
High Pressure Switch Open
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
8-0
Perishable Heat
Pass/Fail/Skip Result, STS, time it takes to heat to 16°C (60°F)
8-1
Perishable Pull Down
Pass/Fail/Skip Result, STS, time it takes to pull down to 0°C (32°F)
8-2
Perishable Maintain
Pass/Fail/Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0
Defrost Test
Pass/Fail/Skip Result, DTS reading at end of test, line voltage, line fre-
quency, time in defrost.
10-0
Frozen Mode Set-up
Pass/Fail/Skip Result, STS, time unit is in heat.
10-1
Frozen Mode Pull Down
Pass/Fail/Skip Result, STS, time to pull down unit to -17.8°C (0°F).
10-2
Frozen Mode Maintain
Pass/Fail/Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.
Содержание 69NT40-541-001
Страница 2: ......
Страница 4: ......
Страница 10: ...T 316 vi...
Страница 14: ......
Страница 20: ......
Страница 24: ......
Страница 36: ......
Страница 79: ...5 9 T 316 Figure 5 3 Controller Operation Perishable Mode Figure 5 4 Controller Operation Frozen Mode...
Страница 138: ......
Страница 141: ...8 3 T 316 Figure 8 2 SCHEMATIC DIAGRAM...
Страница 142: ...T 316 8 4 Figure 8 3 SCHEMATIC DIAGRAM Units with Single Evaporator Fan Capability...
Страница 144: ...T 316 8 6 Figure 8 5 SCHEMATIC DIAGRAM Emergency Bypass To ST10 To TRX2 To QC1 To QC1 To QC1 To MC6 CONTROLLER...
Страница 150: ......
Страница 154: ......
Страница 155: ......