T-316
4–32
Table 4–8 DataCORDER Function Code Assignments
CODE #
TITLE
DESCRIPTION
NOTE
Inapplicable Functions Display “-----”
To Access: Press ALT. MODE key
dC1
Recorder Supply
Temperature
Current reading of the supply recorder sensor.
dC2
Recorder Return
Temperature
Current reading of the return recorder sensor.
dC3-5
USDA 1,2,3
Temperatures
Current readings of the three USDA probes.
dC6-13
Network Data
Points 1-8
Current values of the network data points (as configured). Data point 1 (Code
6) is generally the humidity sensor and its value is obtained from the Controller
once every minute.
dC14
Cargo Probe 4
Temperature
Current reading of the cargo probe #4.
dC15-19
Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24
Temperature Sen-
sors 1-5 Calibration
Current calibration offset values for each of the five probes: supply, return,
USDA #1, #2, and #3. These values are entered via the interrogation program.
dC25
Future Expansion
This code is for future expansion, and is not in use at this time.
dC26,27
S/N, Left 4, Right 4
The DataCORDER serial number consists of eight characters. Function code
dC26 contains the first four characters. Function code dC27 contains the last
four characters. (This serial number is the same as the Controller serial number)
dC28
Minimum Days Left
An approximation of the number of logging days remaining until the
DataCORDER starts to overwrite the existing data.
dC29
Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30
Date of last Trip start
The date when a Trip Start was initiated by the user. In addition, if the system
goes without power for seven continuous days or longer, a trip start will auto-
matically be generated on the next AC power up.
dC31
Battery Test
Shows the current status of the optional battery pack.
PASS
: Battery pack is fully charged.
FAIL
: Battery pack voltage is low.
dC32
Time: Hour, Minute
Current time on the real time clock (RTC) in the DataCORDER.
dC33
Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34
Date: Year
Current year on the RTC in the DataCORDER.
dC35
Cargo Probe 4
Calibration
Current calibration value for the Cargo Probe. This value is an input via the in-
terrogation program.
Содержание 69NT40-541-001
Страница 2: ......
Страница 4: ......
Страница 10: ...T 316 vi...
Страница 14: ......
Страница 20: ......
Страница 24: ......
Страница 36: ......
Страница 79: ...5 9 T 316 Figure 5 3 Controller Operation Perishable Mode Figure 5 4 Controller Operation Frozen Mode...
Страница 138: ......
Страница 141: ...8 3 T 316 Figure 8 2 SCHEMATIC DIAGRAM...
Страница 142: ...T 316 8 4 Figure 8 3 SCHEMATIC DIAGRAM Units with Single Evaporator Fan Capability...
Страница 144: ...T 316 8 6 Figure 8 5 SCHEMATIC DIAGRAM Emergency Bypass To ST10 To TRX2 To QC1 To QC1 To QC1 To MC6 CONTROLLER...
Страница 150: ......
Страница 154: ......
Страница 155: ......