INVISI
™
SERIES II
Installing the Tank -
237 061
Induct Access
Caroma Invisi II Integrated
Wall Hung Bowl Bracket
Finished Floor Level
15.75" - 16.5"
(400mm - 420mm)
Datum A
Access box converted
to top (refer to page 11)
Accurate positioning of the soil pipe
relative to studwork is essential
WP support
& flange nut
assembly, use
as required
6.7" (170mm) Max. from finished wall with the
waste pipe provided with this pack
5.3"
(135mm)
Max. with
Supplied flush pipe
Ensure at least 300mm
clearance above top of
tank for service access
Height to
centre of the
selected bowl's
waste outlet
Centre line buttons
(standard mounting)
1.8"
(45mm) – Water supply connection
22.9"
(582mm)
Supplied
to centre of inlet
(adjustable from 16.2" - 22.9"
or 412mm - 582mm)
Height to
centre of the
selected bowl's inlet
Waste Pipe Adjustment
Allows for the 4" (100mm) soil pipe being
set back from the wall face up to 1" (25mm).
1
2
3
8
Refer to pages 6 to 7 for installation
procedure.
NOTE: For Induct Structural Wall
installations, the Invisi II tank pack
237 060 in conjunction with the D788
Sanifix Bolt Through Wall Bowl Bracket
(Code No. 687 788) is recommended,
as pictured adjacent.