INVISI
™
SERIES II
Installing the Tank -
237 062
Under Counter Access
Counter Top
Basin
Centre Line Buttons
(standard mounting)
The Bracket system is suitable for installation only where
non compressible wall materials are used.
Accurate positioning of the soil pipe
relative to studwork is essential.
To achieve a minimum under counter cavity of 3.5" (90mm)
the soil pipe must be accurately centred.
Finished Floor Level
Height to
centre of the
selected bowl's
waste outlet
Datum A
22.9"
(582mm)
Supplied
to centre of inlet
(adjustable from
16.2"-22.9"
(412-582mm)
)
Height to
centre of the
selected bowl's inlet
33.5"
(850mm)
Min.
2.2"
(55mm)
Min.
- to underside
of counter top
Finished wall
Top Mount Button
Panel & Access
Front Mount Button
Panel & Access
1.8"
(45mm)
Max
.
from top of bench to top
of tank for
Top Mount
Button Installation
WP Support & Flange Nut
Assembly, use as required
(Refer to instruction supplied
separately).
Access box converted
to top (refer to page 12)
0.2"
(5mm)
Min.
1.8"
(45mm)
Max.
Wall Thickness
15.75" - 16.5"
(400mm - 420mm)
1.8"
(45mm) – Water Supply Connection
3.5"
(90mm)
Min. Cavity
Front Mount Button Installation
3.9"
(100mm)
Min. Cavity
Top Mount Button Installation
Refer to pages 6 to 7 for installation
procedure.
6¼
8¼
Access box converted to top
(refer to page 11)
The Bracket system is suitable for
installation only where non-compressible
wall materials are used.
10