INVISI
™
SERIES II
Servicing - Outlet Valve
1
2
3
14
Wash seal to remove any dirt and inspect
for damage. If necessary remove seal
and replace (Spare Part Kit 237 070).
237 070S
Ensure water is turned off and
remove Outlet Valve from tank as
per the instructions on page 13.
Re-assemble complete Outlet Valve and
refit into tank. Turn water back on, wait for
tank to fill and test both buttons to ensure
they activate the outlet valve.
Seal
• Servicing is only required in instances where outlet valve operation is found to be faulty.
Servicing Requirements
• If Outlet Valve leaks ► Inspect seal for damage and replace if necessary.
• If short flushing ► Check pneumatic tubes are pushed into the bridge and buttons
• If any other issues arise ► Consult a plumber or Caroma After Sales Service.
Troubleshooting Guide
• Caroma Invisi II Outlet Valve compatible Spare Part Kits are:
237 072
Containing -
1 x Complete 4.8/3L Replacement Outlet Valve
237 070
Containing -
Diaphragm Seal
(10 Pack)
237 070S
for Single Diaphram Seal
Refer to
Maintenance & Spare Parts Instructions
Spare Parts Information
Maintenance & Spare Parts Instructions