Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 07/18
31
CERTUS Installation Manual
⇒
T
Input_filter
= max filtering time from among those set on project inputs (see “INPUTS” section”).
Enclosure
Description
Electronic housing max 24 pole,
with locking latch mounting
Enclosure material
Polyamide
Enclosure protection class
IP20
Terminal blocks protection class
IP2
Fastening
Quick coupling to rail according to EN 60715
Dimensions (h x l x d)
108 x 22.5 x 114.5
CMM Module
PFHd (IEC 61508:1998)
6.06E-9
Rated voltage
24VDC ± 20%
Dissipated power
3W max
Unit enable (No./description)
2 / PNP active high “type B” according to EN 61131-2
Digital INPUTS (No./description)
8 / PNP active high according to EN 61131-2
INPUT FBK/RESTART (No./
description)
2 / EDM control / possible Automatic
or Manual operation with RESTART button
Test OUTPUT (No./description)
4 / to check for short-circuits - overloads
Digital OUTPUTS (No./description)
2 / programmable - PNP active high3
OSSD (No./description)
2 pairs / solid state safety outputs PNP active high
400mA@24VDC max
SLOT for CMC card
Available
Connection to PC
USB 2.0 (Hi Speed) - Max cable length: 3m
Connection to slave units
via SCC 5-way Carlo Gavazzi proprietary bus
C 8I 2O Module
PFHd (IEC 61508:1998)
5.72E-9
Rated voltage
24VDC ± 20%
Dissipated power
3W max
Digital INPUTS (No./description)
8 / PNP active high according to EN 61131-2
Test OUTPUT (No./description)
8 / to check for short-circuits - overloads
Digital OUTPUTS (No./description)
2 / programmable - PNP active high
OSSD (No./description)
2 pairs / solid state safety outputs:
PNP active high – 400mA@24VDC max
Connection to CMM
via SCC 5-way Carlo Gavazzi proprietary bus