Product Description
C220 / C300 / C400
14
Service Instructions
03.22
NOTICE!
For adjustments of certain applicator functions, release the
control valves in the pneumatic system.
The control valves are accessible only with dismounted cover.
3
4
11
9
7
10
8
6
2
1
1
5
1
Figure 5
Loosen screws (1) and remove cover (2).
The compressed air control valves can be controlled manually
with integrated switch (6 - 11).
Three-way valve (3) to control the lift cylinder
If the printer is switched on the valve will controlled by electronics and
the tamp will hold in the upper end position (home position). If the
valve switched the tamp will move in the lower end position (labelling
position). In normal labelling operation the movement back in the
upper end position will start by a signal from labelling sensor (lower
end position sensor).
NOTICE!
The switching by hand of this valve has only a result in case
of a switched off printer.
Switching the valve by hand over switch 6 the tamp will move down up
to the lowest possible position because no control is made by the
sensor.
Switching the valve by hand over switch 7 the tamp will move up.
Control valves
Содержание C220
Страница 1: ......
Страница 4: ...Table of Contents C220 C300 C400 4 Service Instructions 03 22 ...
Страница 8: ...Introduction C220 C300 C400 8 Service Instructions 03 22 ...
Страница 16: ...Product Description C220 C300 C400 16 Service Instructions 03 22 ...
Страница 26: ......
Страница 32: ...Troubleshooting C220 C300 C400 32 Service Instructions 03 22 ...
Страница 34: ...Block Diagram C220 C300 C400 34 Service Instructions 03 22 ...
Страница 36: ...Pneumatic plan C220 C300 C400 36 Service Instructions 03 22 ...
Страница 38: ...Terminal Diagram of PCB C220 C300 C400 38 Service Instructions 03 22 Figure 20 ...
Страница 40: ...Environmentally Friendly Disposal C220 C300 C400 40 Service Instructions 03 22 ...
Страница 43: ......
Страница 44: ......