5
Troubleshooting
5.1 Sensor Labelling Position / Sensor Start Position
The sensor labelling position and the sensor start position show the
activation by a LED integrated in the sensor. This LED glows in case
of activation.
1 2
3 4 5
Figure 14
1. Loosen the locking ring by loosen the screw (1).
2. Open the compressed air supply.
3. Switch on the printer and the cylinder is moved to the maximum
position (upper end position).
4. Move the locking ring with sensor (2) so that the LED at the
sensor glows.
5. Fix the sensor position by tightening the screw (1) of locking ring.
1. Loosen the screw (5) at the sensor and switch on the printer.
2. Adjust the sensor (4) in a way that it is activated if the adapter pin
(3) was pressed approx. 5 mm into the pad component. Up to
pressing of the adapter pin into the pad component the LED glows
at the sensor.
In the activating condition the LED goes out.
Adjust the sensor
start position (2)
–
upper end position
sensor
Adjust the sensor
labelling position (4)
–
lower end position
sensor
Содержание C220
Страница 1: ......
Страница 4: ...Table of Contents C220 C300 C400 4 Service Instructions 03 22 ...
Страница 8: ...Introduction C220 C300 C400 8 Service Instructions 03 22 ...
Страница 16: ...Product Description C220 C300 C400 16 Service Instructions 03 22 ...
Страница 26: ......
Страница 32: ...Troubleshooting C220 C300 C400 32 Service Instructions 03 22 ...
Страница 34: ...Block Diagram C220 C300 C400 34 Service Instructions 03 22 ...
Страница 36: ...Pneumatic plan C220 C300 C400 36 Service Instructions 03 22 ...
Страница 38: ...Terminal Diagram of PCB C220 C300 C400 38 Service Instructions 03 22 Figure 20 ...
Страница 40: ...Environmentally Friendly Disposal C220 C300 C400 40 Service Instructions 03 22 ...
Страница 43: ......
Страница 44: ......