Error
Cause
Solution
Loss of blow air
The valve is not activated.
The LED at the valve does not
glow.
Defective applicator PCB.
Change the applicator PCB.
Insufficient pressure at pad with
an activated valve.
Defective pneumatic tubes.
Replace the pneumatic tubes.
Loss of applicator function
Compressed air failure.
Check the connections.
Defective applicator PCB.
Change the applicator PCB.
Loss of support air
Valve is not controlled.
Defective applicator PCB.
Change the applicator PCB.
Insufficient pressure at blow
tube with an activated valve.
Defective pneumatic tubes.
Change the pneumatic tubes.
Defective or wrong adjusted
throttle valve.
Adjust and/or change the
throttle valve.
Permanent error at the label
transfer via pad
Faulty pad position in transfer
position to the peel off edge of
the printer.
Correct position (backward
edge of pad approx. 1 mm
above the peel off edge of
printer).
Insufficient or missing vacuum.
Adjust the vacuum at throttle
valve.
Support air does not blow
exactly the label to the pad.
Adjust the blow tube.
Adjust the pressure of support
air via throttle valve 'support
air'.
Adjust the switch on delay.
Содержание C220
Страница 1: ......
Страница 4: ...Table of Contents C220 C300 C400 4 Service Instructions 03 22 ...
Страница 8: ...Introduction C220 C300 C400 8 Service Instructions 03 22 ...
Страница 16: ...Product Description C220 C300 C400 16 Service Instructions 03 22 ...
Страница 26: ......
Страница 32: ...Troubleshooting C220 C300 C400 32 Service Instructions 03 22 ...
Страница 34: ...Block Diagram C220 C300 C400 34 Service Instructions 03 22 ...
Страница 36: ...Pneumatic plan C220 C300 C400 36 Service Instructions 03 22 ...
Страница 38: ...Terminal Diagram of PCB C220 C300 C400 38 Service Instructions 03 22 Figure 20 ...
Страница 40: ...Environmentally Friendly Disposal C220 C300 C400 40 Service Instructions 03 22 ...
Страница 43: ......
Страница 44: ......